Room Air Conditioner
Installation and Operation
Manual
KP Line
115 Volts
KP05
KP06
Registering Your Room Air Conditioner
Model information
can be found on the name plate located on the
side of the unit near the control
panel.
Please complete
and mail
the owner registration
card furnished
with this product or register
on-line at www.friedrich.com
(USA only). For your future
convenience,
record the model information
here.
MODEL NUMBER
SERIAL NUMBER
PURCHASE
DATE

Advertisement

loading
Need help?

Need help?

Do you have a question about the KP06 and is the answer not in the manual?

Questions and answers

Summary of Contents for Friedrich KP06

  • Page 1 Please complete and mail the owner registration card furnished with this product or register on-line at www.friedrich.com (USA only). For your future convenience, record the model information here. MODEL NUMBER SERIAL NUMBER...
  • Page 3: Table Of Contents

    Table of Contents Introduction .................. 2 Safety Precautions ............... 3 How to operate your Friedrich ........... 5 Features and Installation ............. 7 Installation Instructions ............... 8 Troubleshooting Tips ..............11 Warranty ..................12...
  • Page 4: Introduction

    Introduction Before Operating Your Unit Make sure the wiring is adequate for your unit. If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in figure 1. DO NOT use an extension cord.
  • Page 5: Safety Precautions

    • If the power cord is damaged, it must generation. be replaced by the manufactureror a Friedrich-certifiedservice agent. ® , it will cause electric shock or fire , It will cause electric shock. ° This could lead to health problems.
  • Page 6 [/k c,,,UT, , They are sharp and may cause . Water may enter the unit and . Since the fan rotates at high an injury. degrade the insulation. It may speed during operation, it may cause an electric shock. cause an injury. .
  • Page 7: How To Operate Your Friedrich

    How to operate your Friedrich The controls willlook like the following. Control and Remote Control Operations TEMPERATURE SETTING • These buttons controlthe temperature of the room. The temperaturecan be set within a range of 60°F to 86°F, in incrementsof I°F.
  • Page 8 ConsuLta certified Friedrich service agent for more information. Fig. 3 • HOW TO REMOVE THE FRONT GRILLE 1. Pull the inlet grille forward.
  • Page 9: Features And Installation

    Features and Installation Learning the key components will help you properly install the unit. Features 1. CABINET 6. AIR FILTER 2. HORIZONTAL AIR DEFLECTOR 7. CONTROL BOARD 3. COOL AIR DISCHARGE 8. AIR INTAKE 4. FRONT GRILLE 9. UPPER GUIDE 5.
  • Page 10: Installation Instructions

    Installation Instructions Window Requirements NOTE: All supporting parts should be secured to firm wood, masonry, or metal. 1. This unit is designed for installation in standard double hung windows with actual opening widths of 22" to 36". The upper and lower sash must open sufficiently to allow a clear vertical opening of 14" from the bottom of the sash to the window sill.
  • Page 11 A. BEFORE INSTALLATION 1. Insert the guide panels into the guides of the air conditioner. Fasten the curtains to the unit with TYPE A screws (TYPE A) as shown Fig. 6. 2. Cut the adhesive-backed seal strip (TYPE D) to the window width.
  • Page 12 WINDOW b. While steadying the air conditioner, carefully bring UPPER GUIDE the window sash down behind the upper guide of the air conditioner, as shown in Fig. 11. ABOUTII4" 4. SECURE THE GUIDE PANELS Extend the guide panels (TYPE F) to fill the window GUIDE opening using 4 screws (TYPE B) to secure them, as shown in Fig.
  • Page 13: Troubleshooting Tips

    Troubleshooting Tips Troubleshooting Tips save time and money! Review the chart below first and you may not need to call for service. Normal Operation • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high.
  • Page 14: Warranty

    Sealed Refrigeration System; PROVIDED FRIEDRICH will not pay the cost of diagnosis of the problem, removal, freight charges and transportation of the air conditioner to and from the Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System.
  • Page 15 FRIEDRICH AIR CONDITIONING Visit our web site at www.friedrich.com Post Office Box 1540 * 4200 N. Pan Am Expressway * San Antonio, Texas 78295-1540 • (210) 3574400 * FAX (210) 3574480 P/NO.: 3828A20126F...

This manual is also suitable for:

Kp05