1. After the 165 error message, the machine appears to hang.
Place the Reference Diskette in drive A: and press F1. The
screen clears and the banner screen appears. Press Enter to
continue. The following message displays:
Use Automatic Configuration (Y/N)? N
2. Answer no to the automatic configuration question. The
main menu displays:
Main Menu
Because the MEGAPORT/2 installation modifies the Refer-
ence Diskette, a backup of the diskette should be made. A
blank 1.44 MB diskette that is not write protected is re-
quired. Select option #2 and follow the instructions. This
step may be skipped if a backup copy is currently being
used.
After completing the backup, store the original Reference
Diskette in a safe place. Continue using the backup.
3. Reboot the system using the backup reference diskette and
select option 5, Copy an option diskette, from the
main menu.
When asked, insert the new Option Diskette into drive A:
and the @6384.ADF file is copied into RAM. Then when
asked, insert the Reference Diskette into drive A and the
@6384.ADF file is appended to the Reference Diskette.
4. After copy is finished and the system returns to the main
menu, the configuration can be set. Select option 3, Set
configuration, from the main menu.
The set configuration menu appears. From this menu,
select option 5, Run automatic configuration.
Set Configuration
16
1. Learn about the computer.
2. Backup the Reference Diskette.
3. Set Configuration.
4. Set features.
5. Copy an option diskette.
6. Test the computer.
1. View configuration.
2. Change configuration.
3. Backup configuration.
4. Restore configuration.
5. Run automatic configuration
Equinox MEGAPORT Hardware Reference Manual