Micro Switch; Reflex Sensor - Avery Dennison Power Stacker Manual

Table of Contents

Advertisement

The sensor pairs placed in the front plate are numbered as following

Micro switch

The micro switch (lower end position) can be removed after the cover of the power stacker is
removed and the wire is removed from the CPU board.

Reflex Sensor

The sensor pairs are glued into the front plate ( with Loctite ....) and a special part. If one of
the sensor is defect it has to be removed carefully, the hole has the be cleaned and the new
sensor glued in.
Attention:
The sensor has to stay 1 mm behind the front plate.
10/06
User / Service Manual Power Stacker
sensor 1
sensor 2
sensor 3
sensor 4
Rev. 1.09
sensor 1mm
behind the plate
20