General Information; Commonly Used Acronyms And Abbreviations; About The Unit - Trane Voyager CV Installation And Maintenance Manual

27.5 to 50 ton 60 hz 22.9 to 41.7 ton 50 hz cv, vav, or sz vav rooftop air conditioners with reliatel controls, r-410a refrigerant
Table of Contents

Advertisement

General Information

Commonly Used Acronyms and
Abbreviations
BAS
= Building Automation System
CFM
= Cubic Feet per Minute
CLV
= Cooling Valve (Reheat only)
COMM = Module Designation for TCI/LCI
CV
= Constant Volume
CW
= Clockwise
CCW
= Counterclockwise
DSP
= Direct Space Pressure control
DTS
= Discharge Air Sensor
DWU = Daytime Warm-up
E/A
= Exhaust Air
ECA
= Economizer Actuator
EET
= Entering Evaporator Temperature Sensor
F/A
= Fresh Air
FFS
= Fan Failure Switch
ICS
= Integrated Comfort System (See BAS)
IDM
= Indoor Fan Motor
I/O
= Input/Output
Installation, Operation and Maintenance manual (Ships
IOM
=
with each unit)
LCI
= LonTalk® Communication Interface
LCI-R = LonTalk Communication Interface with ReliaTel
LH
= Left Hand
MAS
= Mixed Air Sensor
MAT
= Mixed Air Temperature
MCHE
Microchannel
MWU = Morning Warm Up
NSB
= Night Setback (programmable ZSM BAYSENS119*)
O/A
= Outside Air
OAH
= Outside Air Humidity
OAT
= Outside Air Temperature

About the Unit

Overall unit dimensional data is illustrated in
p. 13
to
Figure 9, p.
17. Each package rooftop unit ships
fully assembled and charged with the proper refrigerant
quantity from the factory. They are controlled by a
microelectronic unit control processor. Several solid state
modules are grouped to form the "Control System" . The
number of modules within any given control system will
be dependent upon the options and accessories ordered
with the unit. Acronyms are used extensively throughout
this manual when referring to the "Control System" .
RT-SVX34F-EN
PGA
= Power Exhaust Actuator
PSIG
= Pounds Per Square Inch Gauge pressure
PHM
= Phase monitor
R/A
= Return Air
RAH
= Return Air Humidity
RAT
= Return Air Temperature sensor
RH
= Right Hand
RHP
= Reheat Pumpout Solenoid
RHV
= Reheat Valve
RLP
= Reheat Low Pressure Cutout
RPM
= Revolutions Per Minute
RTAM
= ReliaTel Air Handler Module
RTDM
= ReliaTel Dehumidification Module
RTVM
= ReliaTel Ventilation Module
RTOM
= ReliaTel Options Module
RTRM
= ReliaTel Refrigeration Module
S/A
= Supply Air
SPC
= Space Pressure Calibration Solenoid
SPP
= Space Pressure Transducer
SPT
= Static Pressure Transducer
SZVAV = Single Zone Variable Air Volume
TCI
= Trane Communication Interface
TCO
= Temperature Cutout
TDL
= Temperature Discharge Limit
VAV
= Variable Air Volume
VFD
= Variable Frequency Drive
VHR
= Ventilation Heat Relay (VAV box relay)
W.C.
= Water Column
XFSP
= Exhaust Fan Setpoint
ZSM
= Sensor, Zone Sensor, Zone Sensor Module, Zone Panel
Basic unit components include:
Figure 1,
Scroll compressors
One (1) Intertwined Evaporator Coil
One (1) Supply Fan
Three (3) to Four (4) Condenser Fans
One (1) Microchannel Condenser Coil
Filters (type is dependent on option selection)
11