2. Download Names Screen
3. Download Statistics Screen
The Download Statistics screen (right) allows the user to
retrieve the AES-2000's building entry log. Each time the
AES-2000 energizes the door strike, it adds to the log,
recording the date, time name/type (tenant allowing the
entry) and code (type of actuation). Up to 1024 entries
can be stored before the oldest entry is written over.
Retrieving just a portion of the log can be accomplished
by entering a "Read Pointer" value for the starting point
and a "Count" value for the ending point. To receive the
AES-2000's existing data, click on "Download" and to
clear all existing data click on "Reset". Clicking "Back" will
return the user to the Data Transmit Screen.
4. Entry Points Screen
D. Recordings
The Recordings screen (right) is used to make an audio
recording of each of the names of the tenants. These are the
recordings that a user will hear when the user is stepping
through the directory of the AES-2000. When in the record
mode, the software will step through each name, displaying it
in large letters, and prompting the user as when to speak.
After each recording is made, the software plays it back auto-
matically, and selects the next name from the list. Completed
recordings are listed in the box on the right hand side. To go
back to the data mode, click on the Back button. To end the
session, click on the Exit button.
The Download Names screen (left) is used to retrieve
the tenant names, phone numbers, access codes and
keyless entry codes that have been previously pro-
grammed into the AES-2000. The "Present ID" box con-
tains the ID number of the first record to be downloaded.
The tenant ID is an unchangeable consecutive number
assigned to the tenant when they were added to the
database. The "Download Count" box contains the total
number of records to be downloaded. Clicking on
"Download" will retrieve all records starting with the
"Present ID" through the Download Count. Once the
records are displayed in the data field, the "File" pull-
down menu can be used to print or save the data.
Clicking on "Clear" will clear data fields and reset the
present ID to 1. Clicking on "Back" will return the user to
the Data Transmit Screen.
If remote ES-3 modules are installed, the Entry Points screen (left) is used to pro-
gram each ES-3. When this screen is invoked, fill in group and rotary switch set-
ting for the ES-3 that you wish to program. It is best to click on Get Status to
retrieve the present settings. Any changes can be entered directly into the data
boxes. For complete ES-3 programming instructions, see the ES-3 Technical
Practice (DOD# 195).