Viessmann VITODENSd 100-W Technical Data Manual page 6

Wb1b series wall-mounted, gas-fired condensing boiler with optional on demand hot water combiplus kit 37 to 118 mbh & 10.8 to 34.5 kw
Table of Contents

Advertisement

Technical Data
Specifications
CombiPLUS (Integrated with the Boiler)
DHW supply temperature
Continuous draw rate
with DCW temp. of 56º F (13º C)
Continuous draw rate
at ∆ t= 63º F (35K)
Maximum allowable working
pressure (potable water)
Test pressure
Connections, DHW and DCW
Connections to boiler supply/return
and to heating supply/return
Dimensions
Overall depth
Overall width
Overall height
Height with pipe connector
Integrated pump flow rate
DHW production @ 23 ft. (9.8 m)
Head pressure
Heating system operation
with system side additional
drop in pressure of max. 6 ft. of
water (1.8 m)
Weight
1
Based on boiler max. output and boiler supply temperature of 176º F (80º C).
2
DCW and DHW temperature rise would be proportional. Maximum DHW supply temperature is 140º F (60º C).
6
(continued)
Boiler Model No.
1
2
NPTM (male) "
NPTM (male) "
USG/min.
USG/min.
ºF (ºC)
USG/h
L/h
USG/h
L/h
psi
psi
inches
mm
inches
mm
inches
mm
inches
mm
L/h
L/h
lbs
kg
Vitodens 100-W, WB1B Technical Data
WB1B 26
140 (60)
99
374
156
589
150
300
b"
c"
9.8
250
17
432
8.7
223
13
331
5.63
1278
6.2
1408
25
11
WB1B 35
140 (60)
147
556
216
800
150
300
b"
c"
9.8
250
17
432
8.7
223
13
331
5.63
1278
6.2
1408
25
11

Hide quick links: