Viessmann VITODENSd 100-W Technical Data Manual page 5

Wb1b series wall-mounted, gas-fired condensing boiler with optional on demand hot water combiplus kit 37 to 118 mbh & 10.8 to 34.5 kw
Table of Contents

Advertisement

Vitodens 100-W, WB1B Technical Data
Specifications
(continued)
Standard heating boiler
(continued)
Gas supply connection
Flue gas
5
Temperature at boiler
return temperature of
86º F (30º C)
-
at rated full load
-
at rated partial load
Temperature at boiler
return temperature of 140º F (60º C)
Flue gas value
Mass flow rate (of flue gas)
- at rated full load
- at rated partial load
Available draught
Flue gas temperature
sensor limit
Average condensate
flow rate
6
with natural gas
- T
/T
=122 / 86º F (50 / 30º C)
S
R
Condensate
connection
7
Boiler flue gas
8
connection
Combustion air supply
8
connection
Noise level (at 1 meter)
- at full load
- at partial load
High altitude (factory set)
5
Measured flue gas temperature with a combustion air temperature of 68° F (20° C).
6
Based on typical boiler cycles, including partial load conditions.
7
Requires 1"(25) mm tubing. See Vitodens 100-W Installation Instructions for details.
8
For detailed information refer to the Vitodens Venting System Installation Instructions.
9
For 5,000 to 10,000 ft. (1,500 to 3,048 m) operation, a control programming change is required.
Refer to the Installation and Service Instructions for details.
For information regarding other Viessmann System Technology componentry,
please reference documentation of respective product.
Boiler Model No.
(female)"
USG/day
in (mm)
coaxial
outer Ø in (mm)
single
9
NPTF
ºF (ºC)
ºF (ºC)
ºF (ºC)
lbs/h
kg/h
lbs/h
kg/h
Pa
mbar
ºF (ºC)
L/day
hose
nozzle
Ø in
Ø
(dB)
(dB)
ft. (m)
0-5,000 (0-1,500)
Technical Data
WB1B 26
c
127 (53)
90 (32)
167 (75)
79.2
36.0
33.0
15.0
100
1.0
230 (110)
1.95-2.3
8-9
1
2e (60)
4 (100)
2e (60)
47
40
0-5,000 (0-1,500)
WB1B 35
c
131 (55)
90 (32)
172 (78)
100.1
45.5
33.0
15.0
100
1.0
230 (110)
2.5-2.8
9.4-10.5
1
2e (60)
4 (100)
2e (60)
49
42
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 100-wWb1b seriesWb1b 26Wb1b 35

Table of Contents