Vitodens 100-W, WB1B Technical Data
Heating circuit pumps
DHW Production Planning
With the CombiPLUS for instantaneous DHW heating
or with DHW connections for DHW production via a
stand-alone DHW storage tank, the Vitodens 100 boiler
series offers the right solution for every need.
Various factors must be taken into account when
designing the DHW system, and when deciding between
the DHW production with integrated CombiPLUS and the
standard heating boiler with DHW production via a stand-
alone DHW storage tank.
Options
DHW requirement,
level of comfort and
convenience
Number of draw points One draw point
Distance of draw
points from the boiler/
DHW storage tank
System retrofit
Space requirements
(continued)
DHW requirement for an apartment
DHW requirement for a single-family house
Central DHW requirement for a multi-family house
Decentralized DHW requirement for a multi-family house
Several draw points, non-simultaneous use
Several draw points, simultaneous use
Up to 23 ft. (7 m) (without DHW recirculation line)
With DHW recirculation line
DHW storage tank already installed
Replacement of existing Combi boiler
Minimal space available (installation in alcove)
Adequate space available (boiler room)
Such factors are:
DHW requirement, level of comfort and convenience
g
Number of draw points
g
Distance of draw points from the boiler/DHW storage tank
g
System retrofit
g
Space requirements
g
Gas-fired boiler
with instantaneous
CombiPLUS
production
+ (recommended)
Operation
Gas-fired standard
heating boiler
with stand-alone
DHW storage tank
+
+
0
+
-
+
+
+
+
0
+
0
-
+
+
-
+
-
+
+
+
0
+
+
0 (recommended in certain cases)
- (not recommended)
-
-