Maximum flow temperature correction
Access
&
"System settings"
&
"Program"
&
"Heating circuit"
Room temperature control
A room temperature-dependent con-
trol is possible subject to a room tem-
perature sensor being installed and
enabled (see page 105). This function
must be enabled for this.
Note
The heating curve level and slope can
no longer be adjusted (parameter of
the weather-compensated control
unit), if you have selected "Yes" for
room temperature control.
Setting the slope and level of the heating curve
Operating instructions
Vitocal 300, section "Modifying
the heating characteristics of
the heating circuits"
Integral room temperature controller
Prerequisite: "Room temperature
controller" set to "Yes" (see
page 107).
Integral part of the room temperature
control circuit. A high value results in
a rapid response.
Heating circuit control settings
(cont.)
&
"Heating circuit 1/2"
&
"max. flow correction" (0/=)
Standard setting
Setting range
Access
&
"System settings"
&
"Program"
&
"Heating circuit"
&
"Heating circuit 1/2"
&
"Room control" ("YES"/"NO")
Standard setting
Setting range
Access
&
"System settings"
&
"Program"
&
"Heating circuit"
&
"Heating circuit 1/2"
&
"Integr. room reg." ([/])
10.0 K
0.1 to 10.0 K
NO
YES/NO
107