User Bit Setting Of Internal Generator Time Code; Jam Mode Setting - Fostex PD-6 Operation Manual

Fostex dvd location recorder operation manual model no. pd-6
Hide thumbs Also See for PD-6:
Table of Contents

Advertisement

PD-6 DVD Location Recorder (Chapter 6: TC Setup mode)

User bit setting of internal generator time code

Jam mode setting

86
You can set the time code user bit of the internal generator, which is output
from the [TIME CODE OUT] connector when the [TC OUT] switch is set to
"GEN".
1.
Select the "Gen Ubit: ******" menu and press the [ENTER] key.
The display shows the current internal time code generator setting information,
in which the currently selected user bit output mode flashes (the default mode
is <User>:00 00 00 00>.
2.
Use the [SEL] dial to select the desired user bit, and press the [ENTER] key.
<User>
BG_76:MM (month)/ BG_54:DD (day)/ BG_32:YY (year)/ BG_10:ff (US)
MMDDYYxx
DDMMYYxx
BG_76:DD (day)/ BG_54:MM (month)/ BG_32:YY (year)/ BG_10:ff (EUR)
3.
Press the [EXIT] key to exit the TC Setup mode.
You can set the jam mode which determines what information is jammed.
1.
Select the "JAM mode: ****" menu and press the [ENTER] key.
The display shows the current internal time code generator setting information,
in which the jam mode flashes (the default mode is "BOTH").
2.
Use the [SEL] dial to select the desired mode, and press the [ENTER] key.
Both time code and user bit are jammed.
BOTH
Only time code is jammed. For the user bit, the external time code data is
TC
used.
UBIT
3.
Press the [EXIT] key to exit the TC Setup mode.
the default is 00 00 00 00.
Only the user bit is jammed. For the time code, the external time code data
is used.
flashing
flashing