Setting The Internal Tc Generator Start Time; Force-Jamming To External Time Code - Fostex DV40 Operation Manual

Fostex dvd master recorder operation manual dv40
Hide thumbs Also See for DV40:
Table of Contents

Advertisement

• Setting the internal TC generator start time

To set the internal TC generator start time, you must set the "TC GEN MODE" switch to "FREE
RUN".
1. Use the jog dial (or [SKIP/CURSOR] [|<<] / [>>|] keys) to select "Set Gen. TC?".
The display shows the internal TC generator time code running, together with "Set Gen. TC?".
2. Press the [ENTER/YES] key.
The current time is held and now it can be edited (with the flashing frame digit).
H
GEN
3. Use the jog dial or numeric keys to enter a numeric value.
When using the jog dial to enter a value, you can move the (flashing) digit to be edited by using
the [SKIP/CURSOR] [|<<] / [>>|] keys.
When using the numeric keys to enter a time value, each number is entered from the right digit,
which moves left as additional digits are entered.
You can enter up to "23H 59M 59S **F" (in which ** is one smaller than the frame rate number).
4. After entering the time, press the [ENTER/YES] key.
The internal generator starts from the entered time when the [TC GEN MODE] switch is set to
"FREE RUN".
The DV40 can start recording from the entered time when the [TC GEN MODE] switch is set to
"REC RUN".

• Force-jamming to external time code

You can force-jam the internal generator time code to external time code.
To force-jam to external time code, you must set the "TC GEN MODE" switch to "FREE RUN".
The following procedure assumes that the unit receives external time code from the [TIME
CODE INPUT] connector.
1. Use the jog dial (or [SKIP/CURSOR] [|<<] / [>>|] keys) to select "Force JAM?" and press the
[ENTER/YES] key.
The unit force-jams to external time code and the force-jammed time code value is shown in
realtime.
<Notes>
• When carrying out the above operation, if the [FRAME RATE] switch setting on the front
panel does not match the frame rate of external time code, "Illegal Frame!" appears and the
operation is invalid.
• When carrying out the above operation, if no external time code is available, "Void LTC In!"
appears.
GEN