Download Print this page
Valcom V-1134 Instruction Manual
Valcom V-1134 Instruction Manual

Valcom V-1134 Instruction Manual

All call one-way page unit

Advertisement

Quick Links

ALL CALL ONE-WAY PAGE UNIT
INTRODUCTION
These instructions provide the specifications and
information necessary to install, operate, and maintain
the V-1134, All Call One-Way Page Unit.

SPECIFICATIONS

Purpose
To provide one-way all call page to 34 zones when
used with the V-136RTHF 36 zone page control unit.
Applications
V-136RTHF 36 zone handsfree control unit
Features
One-way all call amplification to 34 zones
Dial 0 for all call
Automatic release of all call unit with two
telephones off hook
Easy installation - 30" plug ended cable provided
Built-in volume control for all call level
NOTE: Unit replaces stations 0 and 39 on 36 zone
control units.
Dimensions/Weight
7.13"H x 5.75"W x 2.13"D
(18.11cm H x 14.61cm W x 5.41cm D)
4 lbs. (1.8 kg)

Power Requirements

-24 Vdc B battery 1 amp maximum
Output
400 milliwatts per speaker
V-1134
DESIGN
General
This unit provides one-way all call page to the
V-136RTHF. The functions and operation of the
intercom unit remain the same as without the all call
unit with exception that dialing "0" energizes the all
call unit and permits a one-way page to all stations of
the intercom.
INSTALLATION
Precautions
All precautions have been taken at the factory to insure
that the equipment functions properly. To insure
proper operation and to prevent equipment damage,
please observe the following:
a) Unplug the power supply before connecting any
wires or cables to the control unit connecting
block.
b) Do not locate the control unit more than 5 feet
from the power supply or closer than 18 inches.
c) Do not use a lamp tester to check signals, use a
voltmeter. A lamp tester when first applied is a
short circuit to electronic circuits.
d) Do not apply power to the control unit until all
connections have been double-checked.
1
VSP-V-1134
Issue 7
947114

Advertisement

loading

Summary of Contents for Valcom V-1134

  • Page 1: Specifications

    ALL CALL ONE-WAY PAGE UNIT INTRODUCTION These instructions provide the specifications and information necessary to install, operate, and maintain the V-1134, All Call One-Way Page Unit. SPECIFICATIONS Purpose To provide one-way all call page to 34 zones when used with the V-136RTHF 36 zone page control unit.
  • Page 2: Power Connections

    30-29, 0, and 5-9 resistive ground supplied by the Y/BN lead of the must be voice signaling. Bells or buzzers V-1134 (ICM connector) back to the O/V lead of the must be connected as excluded speakers V-1134 (ICM connector). The V-1134 operates a (See Figure 2).
  • Page 3 PROBLEMS PROBABLE CAUSES AND CORRECTIONS All call feature inoperative. Verify connection to proper plugs on V-1134. If plugs are reversed, intercom will operate, but all call function will not. Plug cable from crossconnect block directly into V-136RTHF bypassing V-1134 and check for proper operation of intercom.
  • Page 4 This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation, or use of the product.