Connections and Wiring
IR/Serial Connections and Wiring
You can connect up to eight IR- or serial-controllable devices to the IR/Serial connectors (ports 8-15). These connectors
accept an IR emitter (CC-NIRC) that mounts on the device's IR window, or a mini-plug
(CC-NSER) that connects to the device's control jack. The IR/Serial connector wiring specifications are listed in the
following table.
IR/Serial Connector Wiring Specifications
No.
Port
1
8
2
9
3
10
4
11
5
12
6
13
7
14
8
15
Input/Output (I/O) Connections and Wiring
The I/O port responds to switch closures or voltage level (high/low) changes, or can be used for logic-level outputs.
You can connect up to eight devices to the I/O connectors (port 16). A contact closure between GND and an
I/O port is detected as a Push. When used for voltage inputs, the I/O port detects a low (0-1.5 VDC) as a Push, and a high
(3.5-5 VDC) signal as a Release. When used for outputs, the I/O port acts as a switch to GND and is rated at 200 mA @
12 VDC.


The following table lists the wiring specifications for the I/O connectors.
I/O Port Wiring Specifications
Pin
Signal
1
GND
2
I/O 1
3
I/O 2
4
I/O 3
5
I/O 4
6
I/O 5
7
I/O 6
8
I/O 7
9
I/O 8
10
12 VDC
2
Signal
GND (-)
Signal 1 (+)
GND (-)
Signal 2 (+)
GND (-)
Signal 3 (+)
GND (-)
Signal 4 (+)
GND (-)
Signal 5 (+)
GND (-)
Signal 6 (+)
GND (-)
Signal 7 (+)
GND (-)
Signal 8 (+)
The PWR pin (+12VDC @ 200 mA) is designed as a power output for the PCS2 or VSS2 (or equivalent).
The GND connector is a common ground and is shared by all I/O ports.
Function
Signal GND
Input/output
Input/output
Input/output
Input/output
Input/output
Input/output
Input/output
Input/output
PWR
Function
Signal GND
IR/Serial data
Signal GND
IR/Serial data
Signal GND
IR/Serial data
Signal GND
IR/Serial data
Signal GND
IR/Serial data
Signal GND
IR/Serial data
Signal GND
IR/Serial data
Signal GND
IR/Serial data