Troubleshooting Sensorsafe Board And Sensors - Follett 110 Series Installation & Service Manual

110 series – 220v 60hz/230v 50hz ice and water dispensers
Hide thumbs Also See for 110 Series:
Table of Contents

Advertisement

Troubleshooting SensorSAFE board and sensors

Board guide
LEDs, when illuminated, indicate the following:
PWR
(board power)
CLN
(cleaning, no dispensing cycle)
ICE
(ice dispensing activated)
WTR
(water dispensing activated)
Problem: Does not dispense ice or water
Action
Check LEDs on control
board
Place cup under drop
zone
Problem: Dispenses ice or water continuously
Action
Check LEDs on control
board
LED Status
PWR
CLN
OFF
OFF
ON
ON
ON
OFF
ON
OFF
LED Status
PWR
CLN
ON
OFF
ON
OFF
Terminals:
L1
(incoming power, hot)
L2
(neutral terminals)
WTR
(power terminal for water solenoid)
SOL
(power terminal for dispense gate
solenoid) not used
WM
(power terminal for wheel motor)
CLN
(terminals for clean cycle switch)
ICE/WTR
Check circuit breakers and power switch; restore
OFF
power or replace defective switch
Depress clean switch located under left side of front
OFF
cover to return board to normal operation
Troubleshoot appropriate lens/sensor and replace if
OFF
required (see Lens/Sensor Troubleshooting below)
Verify power on appropriate output terminal
ON
(WTR SOL or WM) on control board and replace
board if required; if board tests okay, troubleshoot
appropriate dispenser component
ICE/WTR
Troubleshoot appropriate lens/sensor and replace if
ON
required (see Lens/sensor troubleshooting below)
If there is power on any output terminal (WTR, SOL
OFF
or WM) on control board, replace board
Remove lens protective cover; adjust funnel so water
doesn't drip down lens or behind splash panel
17
Solution
Solution