How unit works — SensorSAFE models
SensorSAFE models provide "touchless" ice and water dispensing. When a container is placed within the actuation
zone below the ice or water chute on SensorSAFE dispenser models, an infra-red signal reflects off the container and is
detected by the sensor. The sensor then sends a signal to the control board to activate the appropriate components to
dispense ice or water. LEDs on the board indicate when the board is receiving a signal from the sensors.
A safety, shut-off feature automatically shuts off dispensing after one minute of continuous activation. Dispensing can be
restarted by moving the container away and then returning it to the actuation zone.
Dispensing can be temporarily suspended for cleaning by depressing and releasing the clean switch, located under the
left side of the top front cover. Depressing and releasing the button a second time will return the dispenser to normal
operating state. If the clean switch is not depressed a second time, the dispenser will automatically resume normal
dispense operation (CLN LED goes out) after two minutes. An LED on the control board will light to indicate that the
dispensing has been suspended by activation of the clean switch.
4x4 JUNCTION BOX
BLACK
ICE MACHINE
POWER
(220/230 VAC)
MAIN POWER SWITCH
BIN SIGNAL
SWITCH
RED
T-STAT
RD
GRN
NEUTRAL
ICE MACHINE
BIN SIGNAL
(16 VDC)
RELAY #2
1
ORANGE
4
15
GREEN/YELLOW
220V 60HZ
BROWN
230V 50HZ
BLUE
WHITE
WHITE
BLUE
WHITE
A
RLY
B
#2
TIMER
WHITE
1
2
3
WHITE
B RLY
A
RELAY #1
RED
#1
4
PUR
WHITE
M
7
1
CLEAN
YELLOW
SWITCH
YELLOW
WHITE
S
ORANGE
BLUE
WHITE
WTR
WHITE
RED
7

Advertisement