Dimensions and clearances
Entire front of icemaker must be clear of obstructions/connections to allow removal.
1" (26mm) clearance above icemaker for service.
1" (26mm) minimum clearance on sides.
The intake and exhaust air grilles must provide at least 170 sq in (968 sq cm) of open area.
Air-cooled model HCC1400A icemakers – 18" (458mm) minimum clearance between discharge and air
intake-grilles.
Front View
Air intake
Side View
21.28" (541mm)
23.50"
(597mm)
Easton Pennsylvania
CORPORATION
MODEL
SERIAL NO
PART NO
FULL LOAD AMPS
VOLTS
HZ
SINGLE
PHASE
Stock Module Identification Plate
208264
MOTOR COMPRESSOR THERMALLY PROTECTED
REFRIGERANT
CHARGE
OZ
Module No.
Product
DESIGN PRESSURE HIGH SIDE
LOW SIDE
PSIG
Service No.
MIN. BRANCH CIRCUIT AMPACITY
AMPS
U
U
L
L
NSF
MADE IN
MAX. BRANCH CIRCUIT FUSE SIZE
AMPS
R
R
THE USA
C
21.05" (535mm)
23.8" (580mm)
Ice transport hose connection
NEMA 6-20
right angle
Air exhaust
both sides
G
1/4" FPT
condenser inlet
1/4" FPT
condenser drain
15.56"
(395mm)
6.97"
(177mm)
2.53"
(64mm)
2.72"
(69mm)
3/8" OD push-in water inlet
3/4" MPT drain
6
Back View
Air exhaust
29.63" (753mm)
2.43" (62mm)