  • Page 1 R 17 MANUEL D'UTILISATION GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO OPERATING INSTRUCTIONS ISTRUZIONI D’USO > GEBRUIKSAANWIJZING...
  • Page 2 Dear Sir, Madam, Congratulations on your purchase of this Zibro heater, the number one brand amongst portable heaters. You have purchased a first-class quality product, which will serve you for many years to come. This, of course, provided you use the heater correctly.
  • Page 3: General Directions For Use

    • Wick height lock The right quality of fuel will be assured, when you use Zibro Extra or Zibro Kristal for your heater. • If you change to another brand and/or type of paraffin oil, you must first finish up all the...
  • Page 4: What You Need To Know In Advance

    Only use Class C1 paraffin fuel in accordance with BS2869 Part two, or equivalent. Your heater has been designed for use with high-quality water-free pure paraffin oil, such as Zibro Extra or Zibro Kristal. Only fuels of this kind will ensure clean and proper burning. Lower quality fuel may result in:...
  • Page 5: Filling Fuel

    MANUAL INSTALLING THE HEATER Carefully remove your heater from the box and check the contents. In addition to the heater you also need to have: a manual fuel pump a transportation cap these directions for use batteries Keep the box and the packaging materials (Fig. A) for storage and/or transportation.
  • Page 6: Igniting The Heater

    Take the manual fuel pump and insert the smooth, most rigid tube into the jerrycan. Make sure that it is in a higher position than the removable tank (Fig. H). Insert the ribbed hose into the opening of the removable tank. Lock the valve on top of the pump (turn clockwise).
  • Page 7: Switching Off The Heater

    After having ignited the heater, always check whether the combustion chamber is level, by sliding it slightly to the left and the right by its handle (Fig. E). This should be a smooth movement. If the combustion chamber is not level, this will cause smoke and soot to develop.
  • Page 8: Malfunction, Causes And Solutions

    If the flame height is still too low and the wick is set on position 3, then contact your dealer, or replace the wick, refer to section M. If the flame gets too high after adjus- ting (Fig Q), the wick height lock should be placed one position lower again. Otherwise smoke or soot may be caused.
  • Page 9: Maintenance

    THE HEATER IS BURNING TOO HIGH You are using an incorrect, too volatile type of fuel. Refer to THE RIGHT FUEL (See Section ’What you need to know in advance’). Wick position too high. Reinstall the wick height lock (Section F). MAINTENANCE Your heater needs hardly any maintenance.
  • Page 10: Specifications

    Let the heater cool down. Clean the heater with a damp cloth and then dry it with a dry cloth. Remove the batteries from the holder and store them in a dry place. Clean the fuel filter (refer to section H). Store the heater in a dust-free place, if possible in its original packaging.
  • Page 11: Warranty Provisions

    WARRANTY PROVISIONS Your heater comes with a 24-month warranty starting on the date of purchase. Within this period all defects in material or workmanship will be repaired without any charge. The following provisions shall apply regarding this warranty: We expressly dismiss all other claims for damages, including consequential damages.
  • Page 12: Replacement Of The Wick

    REPLACEMENT OF THE WICK ENSURE THAT THE HEATER IS OFF AND COMPLETELY COOL BEFORE STARTING TO REPLACE THE WICK. Open the lid and remove the removable tank. Remove the batteries from the battery holder. Open the front grill. Remove the combustion chamber from the heater.
  • Page 13 1 1 2 2 a a 1 1 2 2 b b Install the wick to the wick sleeve according to the allo- wed direction engraved on the wick sleeve. Install the wick sleeve (with wick) to the primary air tube.
  • Page 14 1-3 cm.
  • Page 16 +44 1606 837787 tel: +43 7434 44867 fax: +44 1606 837757 fax: +43 7434 44868 email: sales@scottmail.co.uk email: pvgaustria@zibro.com > ITALIA e BELGIË PVG Italy SRL PVG Belgium NV/SA Via Niccolò Copernico 5 Industrielaan 55 50051 CASTELFIORENTINO (FI) 2900 SCHOTEN tel:...