Zibro R 18 E Operation Manual

Zibro R 18 E Operation Manual

Pvg international b.v.

Advertisement

3
2
5
4
>
1
R 18 E
MANUEL D'UTILISATION
GEBRAUCHSANWEISUNG
INSTRUCCIONES DE USO
OPERATING MANUAL
ISTRUZIONI D'USO
GEBRUIKSAANWIJZING
2
14
26
38
50
62

Advertisement

Table of Contents
loading

Summary of Contents for Zibro R 18 E

  • Page 1 R 18 E MANUEL D'UTILISATION GEBRAUCHSANWEISUNG INSTRUCCIONES DE USO OPERATING MANUAL > ISTRUZIONI D’USO GEBRUIKSAANWIJZING...
  • Page 2 Dear Sir, Madam, Congratulations on your purchase of this Zibro heater, the number one brand amongst portable heaters. You have purchased a first-class quality product, which will serve you for many years to come. This, of course, provided you use the heater correctly.
  • Page 3: General Directions For Use

    Fuel has a limited shelf life. Start every heating system season with new fuel. • The right quality of fuel will be assured, when you use Zibro Extra or Zibro Kristal for your heater. Information display • If you change to another brand and/or type of (E-Guard) paraffin oil, you must first finish up all the remaining fuel in the heater.
  • Page 4: What You Need To Know In Advance

    Only use Class C1 paraffin fuel in accordance with BS2869 Part two, or equivalent. Your heater has been designed for use with high-quality water-free pure paraffin oil, such as Zibro Extra or Zibro Kristal. Only fuels of this kind will ensure clean and proper burning. Lower quality fuel may result in:...
  • Page 5: Filling Fuel

    MANUAL INSTALLING THE HEATER Carefully remove your heater from the box and check the contents. In addition to the heater you also need to have: a manual fuel pump a transportation cap these directions for use Keep the box and the packaging materials (Fig. A) for storage and/or transportation.
  • Page 6: Igniting The Heater

    Lock the valve on top of the pump (turn clockwise). Squeeze the pump a few times, until fuel starts flowing into the removable tank. As soon as this happens, there is no need to press any longer. Check the removable tank fuel gauge while filling the tank (Fig.
  • Page 7: Switching Off The Heater

    After having ignited the heater, always check whether the combustion chamber is level, by sliding it slightly to the left and the right by its handle (Fig. E). This should be a smooth movement. If the combustion chamber is not level, this will cause smoke and soot to develop.
  • Page 8: Maintenance

    IRREGULAR FLAME AND/OR SOOT AND/OR SMELLS The combustion chamber has not been positioned correctly. Use the handle to put it level, until you can easily slide it slightly to the left and to the right and the chamber is level. You are using fuel which is past its ‘use by’...
  • Page 9 3. THE WICK To extend the glass fibre wick life, you must occasionally let the heater burn until the tank is completely emptied and the heater extinguishes by itself. Do this when fuel filter you notice that the flame is weakening. The burn-out will cause some smells, so it is recommended that you take the heater outside of the living room.
  • Page 10: Warranty Provisions

    Remove the removable tank from the heater and remove the fuel filter fuel filter (Fig. N). Some drops may leak from the filter; keep a cloth at hand. Store the fuel filter and the removable tank outside the heater. Place the transportation cap into the position of the fuel filter (Fig. O). Press it tight.
  • Page 11: Tips For Safe Use

    Transportation costs and the risks involved during the transportation of the heater or heater components will always be the responsibility of the purchaser. In order to avoid unnecessary costs, we recommend that you always read the ’Directions for Use’ carefully first. In case they offer no solution, please take the heater to your dealer for repair.
  • Page 12: Replacement Of The Wick

    REPLACEMENT OF THE WICK ENSURE THAT THE HEATER IS OFF AND COMPLETELY COOL BEFORE STARTING TO REPLACE THE WICK. Open the lid and remove the removable tank. Remove the batteries from the battery holder. Open the front grill. Remove the combustion chamber from the heater.
  • Page 13 Install the wick to the wick sleeve according to the allo- 1 1 2 2 a a 1 1 2 2 b b wed direction engraved on the wick sleeve. Install the wick sleeve (with wick) to the primary air tube.
  • Page 14 1-3 cm.
  • Page 16 +44 1606 837787 tel: +43 7434 44867 fax: +44 1606 837757 fax: +43 7434 44868 email: sales@scottmail.co.uk email: pvgaustria@zibro.com > ITALIA e BELGIË PVG Italy SRL PVG Belgium NV/SA Via Niccolò Copernico 5 Industrielaan 55 50051 CASTELFIORENTINO (FI) 2900 SCHOTEN tel:...