  • Page 1 R 14 MANUEL D'UTILISATION GEBRAUCHSANWEISUNG INSTRUCCIONES DE USO OPERATING MANUAL > ISTRUZIONI D’USO GEBRUIKSAANWIJZING...
  • Page 2 Dear Sir, Madam, Congratulations on your purchase of this heater. You have purchased a quality product, which will serve you for many years to come. This, of course, provided you use the heater correctly. Please read these Directions for Use first, to ensure the maximum lifetime for your heater.
  • Page 3: General Directions For Use

    • The right quality of fuel will be assured, when you use Zibro Extra or Zibro Kristal for your heater. • If you change to another brand and/or type of paraffin oil, you must first finish up all the...
  • Page 4: What You Need To Know In Advance

    Only use Class C1 paraffin fuel in accordance with BS2869 Part two, or equivalent. Your heater has been designed for use with high-quality water-free pure paraffin oil, such as Zibro Extra or Zibro Kristal. Only fuels of this kind will ensure clean and proper burning. Lower quality fuel may result in:...
  • Page 5: Filling Fuel

    MANUAL INSTALLING THE HEATER Carefully remove your heater from the box and check the contents. In addition to the heater you also need to have: a transportation cap these directions for use Keep the box and the packaging materials (Fig. A) for storage and/or transportation.
  • Page 6: Igniting The Heater

    Take the manual fuel pump and insert the smooth, most rigid tube into the jerrycan. Make sure that it is in a higher position than the removable tank (Fig. H). Insert the ribbed hose into the opening of the removable tank. Lock the valve on top of the pump (turn clockwise).
  • Page 7: Switching Off The Heater

    After having ignited the heater, always check whether the combustion chamber is level, by sliding it slightly to the left and the right by its handle (Fig. E). This should be a smooth movement. If the combustion chamber is not level, this will cause smoke and soot to develop.
  • Page 8: Maintenance

    IRREGULAR FLAME AND/OR SOOT AND/OR SMELLS The combustion chamber has not been positioned correctly. Use the handle to put it level, until you can easily slide it slightly to the left and to the right and the chamber is level. You are using fuel which is past its ‘use by’...
  • Page 9 2. THE IGNITION COIL The ignition coil will have a longer life, if you ignite the heater in the correct manner. Replace the batteries in time and take care not to push in the ignition button with too much force. If the filament is broken, the ignition coil must be broken ignition coil replaced.
  • Page 10: Warranty Provisions

    TRANSPORTATION Take the following measures to avoid fuel leakage during the transportation of the heater: Let the heater cool down. Remove the removable tank from the heater and remove the fuel filter (Fig. O). Some drops may leak from the filter; keep a cloth at hand. Store the fuel filter and the removable tank outside the heater.
  • Page 11: Tips For Safe Use

    The warranty will not apply to damages caused by actions not in compliance with the Directions for Use, neglect, and the use of an incorrect type of fuel, or fuel past its use-by date. The use of incorrect fuel can even be dangerous*. Transportation costs and the risks involved during the transportation of the heater or heater components will always be the responsibility of the purchaser.
  • Page 12: Replacement Of The Wick

    REPLACEMENT OF THE WICK ENSURE THAT THE HEATER IS OFF AND COMPLETELY COOL BEFORE STARTING TO REPLACE THE WICK. Open the lid and remove the removable tank. Remove the batteries from the battery holder. Open the front grill. Remove the combustion chamber from the heater.
  • Page 13 1 1 2 2 a a 1 1 2 2 b b Install the wick to the wick sleeve according to the allo- wed direction engraved on the wick sleeve. Install the wick sleeve (with wick) to the primary air tube.
  • Page 14 1-3 cm.
  • Page 16 Cranage, Middlewich, CW10 9LT UK tel: +43 7434 44867 tel.: +44 1606 837787 fax: +43 7434 44868 fax: +44 1606 837757 email: pvgaustria@zibro.com email: sales@scottmail.co.uk > ITALIA e BELGIË PVG Italy SRL PVG Belgium NV/SA Via Niccolò Copernico 5 Industrielaan 55 50051 CASTELFIORENTINO (FI)