Zibro SP2035 Operating Manual

Pvg international b.v.

Advertisement

Quick Links

SP2035 - SP2041
6
3
FIN
4
>
BRUGSANVISNING
MANUEL D'UTILISATION
KÄYTTÖOHJE
OPERATING MANUAL
ISTRUZIONI D'USO
2
22
42
62
82

Advertisement

Table of Contents
loading

Summary of Contents for Zibro SP2035

  • Page 1 SP2035 - SP2041 BRUGSANVISNING MANUEL D'UTILISATION KÄYTTÖOHJE OPERATING MANUAL ISTRUZIONI D’USO >...
  • Page 2 Dear Sir, Madam, Congratulations on the purchase of your Zibro airconditioner. You have acquired a high quality product that, if used responsibly, will give you many years of pleasure. Please read these instructions for use first in order to ensure the maximum life span of your airconditioner.
  • Page 3: Table Of Contents

    CONTENTS Safety instructions Parts and functions Before operation Instructions for use Air filter Maintenance Trouble shooting Guarantee conditions Technical data READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner pro- perly.
  • Page 4: Safety Instructions

    • Have any repairs and/or maintenance only carried out by a recognised service engineer or your recognised Zibro supplier. Follow the instructions for use and maintenance as indicated in the user manual of this device. • Always remove the plug of the unit from the wall socket when it is not in use.
  • Page 5: Bparts And Functions

    Do not install in the following places: • Heat or steam is generated in the vicinity. • Under influence by the atmosphere containing in excess salt (in coastal area), sulphide gas (in spa), ammonia, steam of high temperature and vapor. •...
  • Page 6 Operating panel / POWER Operating panel The test operation switch is used as an emergency operation switch. EMERGENCY OPERATION (MANUAL) SWITCH. If the wireless remote controlling system is not available (when the wireless remote controller is lost or is out of battery), the air conditioning system is able to continue its operation temporarily.
  • Page 7: Remote Control

    Remote Control TRANSMITTER HORIZONTAL LOUVER BUTTON Sends signals to the receiver of the indoor unit. Air flow direction can be changed horizon- tally with swing movement (right and left) FAN SPEED by each press. INDICATION FAN SPEED BUTTON Indicates the fan speed selected by the fan speed button.
  • Page 8: Cbefore Operation

    7 meters. 2. Attaching filters COMMENT • Never use the airconditioner without the air filter. • Only use suitable Zibro filters. This will prevent damage to your airconditioner. • Suitable filter packages are available at your dealer.
  • Page 9: Instructions For Use

    How to attach the air clean filters a. Open the front panel by pulling upward b. Remove the outer air filters. Push up the center tab of each filter slightly until it is released from the stopper, and remove the filter downward. Air filters Attach the air clean filters.
  • Page 10: Heating Operation

    Cooling/dry operation Press the ON/OFF button Set the operation mode to Cooling , Heating or Dry , by pressing the operation mode button Adjust the setting temperature by pressing the temperature setting buttons. Adjust the fan speed by pressing the fan speed button. When the mode is set at “AUTO”...
  • Page 11: Automatic Operation

    NOTE! • The air will not flow out unless the heat exchanger gets warm enough in order to prevent cold air. • The air conditioner will not start operation for approx. 3 min. in order to protect the compressor even if you press the ON button right after the operation stops. The operation will start automatically in 3 min.
  • Page 12: Air Flow Adjustment

    Air flow adjustment Standard Position Vertical adjustment The vertical louver will move automatically to the suitable position when ON/OFF Approx. 10 degrees Level button is pressed. (Cooling/Dry) Approx. 70 degrees (Heating) Swing of air flow Swing of Air Flow The vertical louver will keep moving within the range illustrated on the right, if Level the vertical louver button is pressed once.
  • Page 13 Programming the “ON Time” Press the “TIME ADJ” 2 times. Adjust the time with the button. The time setting changes in 10-minu- te intervals. Hold the button to fast forward the time. Press the “TIME ADJ” button two times. The setting of “ON Time” is com- plete and the present time appears.
  • Page 14 Press the “TIME ADJ” button once. The setting of “OFF Time” is complete and the present time appears. Press the “ON/OFF” button. Proceed from Step 5 (below) if the unit has been operated or the ON Timer has been set. Press the timer fixing button “ON”.
  • Page 15: Eair Filter

    Emergency and test operation Emergency Operation • The emergency operation is needed only when the remote control can not be used. • When you press the Emergency Operation Switch, you will hear a beep and the emergency operation starts. • Emergency operation is preset for the following two modes, only based on the temperature of the room at the time of operation.
  • Page 16: Fmaintenance

    The filter frame on the backside of the unit can be opened. The Mold-Proof screen filter, the Photo-cataly- tic Anti-odor Filter and the Static Catechin Filter can be installed or removed. The Mold-Proof screen filter has to be cleaned regularly with a vacuum cleaner to avoid blocking of the air flow.
  • Page 17 Screen Filter Cleaning. (once every two weeks) Open the inlet by pulling upward. Remove the screen filter. Push up the filter’s center tab slightly until it is rele- ased from the stopper, and remove the filter downward. Clean the screen filter. Use a vacuum cleaner to remove dusts, or wash the fil- ter with water.
  • Page 18: Trouble Shooting

    TROUBLE SHOOTING CAUTION! In the event of a malfunction (burning smell, etc.) immediately stop operation, disconnect the Power Supply plug and consult sales shop. Before requesting service, perform the following checks: Problem Cause / Solution The system does not start re-operation This is for protection of the system.
  • Page 19: Guarantee Conditions

    Damage caused by not using suitable Zibro filters is not covered by the guarantee. Refrigerant loss and/or leakage because of incompetent (dis)connecting the units is not covered by the guarantee conditions applicable to this product.
  • Page 20: Technical Data

    TECHNICAL DATA Model SP 2035 SP 2041 DC inverter Wall mounted split Type air-conditioner 850-3500 (2930) 800-4100 (3660) Cooling capacity, min-max (nom)* 2700-12000 (10000) 2700-14100 (12500) Cooling capacity, min-max (nom)* BTU/h EE Class* 4,44 4,14 EER* 700-5300 (3870) 700-6100 (5010) Heating capacity, min-max (nom)* 2400-18000 (13200) 2400-20700 (17100)
  • Page 22 Cranage, Middlewich, CW10 9LT UK tel: +43 7434 44867 tel.: +44 1606 837787 fax: +43 7434 44868 fax: +44 1606 837757 email: pvgaustria@zibro.com email: sales@scottmail.co.uk > ITALIA e BELGIË PVG Italy SRL PVG Belgium NV/SA Via Niccolò Copernico 5 Industrielaan 55 50051 CASTELFIORENTINO (FI)

This manual is also suitable for:

Sp2041