Wheelock POWERPATH PS-12/24-8CP Installation Instructions Manual page 20

Power booster
Hide thumbs Also See for POWERPATH PS-12/24-8CP:
Table of Contents

Advertisement

Example 16: Synchronized Multiple PS-12/24-8MP or PS-12/24-8CP Using a Master PS-
12/24-8MP or PS12/24-8CP (in the WHEELOCK SYNC MODE) With Audible
Silence, and Using Input #1
FACP
ALARM CONDITION
FACP
NOTE 1: NAC Input Voltage 8.0 to 33.0VDC Constant.
NOTE 2: OBSERVE DIP SWITCH SETTINGS
Input Selection Switch (Position 1) on OUT1 to OUT4 DIP Switches are shown in the "ON"
Position allowing Input #1 to activate Outputs 1-4, Positions 2-4 are set for "WHEELOCK SYNC MODE"
NOTE 3: Diagram shown with an output circuit (OUT4) on Master POWERPATH used to synchronize the Remote PowerPaths.
NOTE 4: OBSERVE DIP SWITCH SETTINGS
Input Selection Switch (Position 1) on OUT 1 to OUT 4 DIP Switches are shown in the "ON" Position allowing Input #1 to
activate Outputs 1-4. Positions 2-4 are set for "IN>OUT SYNC MODE".
NOTE 5: Jumpers must be placed across "DRY1" and "DRY2" terminals when operating Power Supply using "IN1" or "IN2".
P84515 E
NOTE 2
PROGRAMMED
-
AUDIBLE SILENCE
+
NAC
-
+
NAC INPUT IN
See Figure 1 on Sheet 5 for larger view of PC Board.
L1
GND L2
GND
TB1
F1
115V
SW1
D10
OUT TRB
AC
D8
D9
OUT1
INP1
D13
D15
OUT2
INP2
D14
D16
OUT3
FAULT
D18
D19
OUT4
BATT
SW2
SW3
OUTPUT3
OUTPUT1
R40
IN>OUT SYNC
IN>OUT SYNC
WHEELOCK SYNC
WHEELOCK SYNC
TEMPORAL
TEMPORAL
INPUT SELECT
INPUT SELECT
SW4
12V
OUTPUT2
OUTPUT4
24V
IN>OUT SYNC
IN>OUT SYNC
WHEELOCK SYNC
WHEELOCK SYNC
TEMPORAL
TEMPORAL
INPUT SELECT
INPUT SELECT
SW6
ON
SW5
OFF
ON
OFF
D70
SW8
P84230 REV.
SW9
TB4
IN1+
IN1-
C
NC
RET1+
IN2-
RET2+
RET2-
C
NC
RET1-
IN2+
+
-
TB6
MH8
DRY1
OUT1
TB5
DRY2
NOTE 5
L1
GND L2
GND
TB1
F1
115V
SW1
D10
OUT TRB
AC
D9
D8
OUT1
INP1
D13
D15
R40
OUT2
INP2
D14
D16
OUT3
FAULT
D18
D19
NOTE 4
OUT4
BATT
SW2
SW3
OUTPUT3
OUTPUT1
SW4
IN>OUT SYNC
IN>OUT SYNC
12V
WHEELOCK SYNC
WHEELOCK SYNC
24V
TEMPORAL
TEMPORAL
INPUT SELECT
INPUT SELECT
OUTPUT2
OUTPUT4
IN>OUT SYNC
IN>OUT SYNC
WHEELOCK SYNC
WHEELOCK SYNC
TEMPORAL
TEMPORAL
INPUT SELECT
INPUT SELECT
SW5
ON
SW6
OFF
ON
OFF
D70
SW8
P84230 REV.
SW9
TB4
IN1+
IN1-
C
NC
RET1+
RET1-
IN2+
IN2-
RET2+
RET2-
C
NC
+
-
TB6
MH8
DRY1
TB5
OUT1
DRY2
L1
GND L2
GND
TB1
F1
115V
SW1
D10
OUT TRB
AC
D9
D8
INP1
OUT1
R40
D15
D13
OUT2
INP2
D14
D16
OUT3
FAULT
D18
D19
OUT4
BATT
NOTE 4
SW2
SW3
OUTPUT3
OUTPUT1
IN>OUT SYNC
IN>OUT SYNC
SW4
WHEELOCK SYNC
WHEELOCK SYNC
12V
24V
TEMPORAL
TEMPORAL
INPUT SELECT
INPUT SELECT
OUTPUT4
OUTPUT2
IN>OUT SYNC
IN>OUT SYNC
WHEELOCK SYNC
WHEELOCK SYNC
TEMPORAL
TEMPORAL
INPUT SELECT
INPUT SELECT
SW5
SW6
ON
OFF
ON
OFF
D70
SW8
P84230 REV.
SW9
TB4
IN1+
IN1-
C
NC
NC
RET1+
RET1-
IN2+
IN2-
RET2+
RET2-
C
TB6
+
-
MH8
DRY1
OUT1
TB5
DRY2
MASTER
TB2
DC
-
+
AUX
RESET
TB3
SW7
W1
NO
C
NC
+
-
+
-
+
-
+
-
MH9
AUX
OUT2
OUT3
OUT4
NOTE 3
REMOTE
TB2
DC
-
+
AUX
RESET
TB3
SW7
W1
+
-
NO
C
NC
+
-
+
-
+
-
MH9
AUX
OUT2
OUT3
OUT4
NOTE 5
REMOTE
TB2
DC
-
+
AUX
RESET
TB3
SW7
W1
+
-
NO
C
NC
+
-
+
-
+
-
MH9
AUX
OUT3
OUT4
OUT2
NOTE 5
Sheet 20 of 23

Advertisement

Table of Contents
loading

Table of Contents