F
Replace the cover as shown.
G
Rotate the separation corona stop-
per (green) to the left to secure the
cover.
H
Remove the red holder of the new
feed unit.
I
Push in the new feed unit as
shown.
TKSM110N
J
Close the ADF cover making sure
it clicks firmly into place.
K
Clear the "PM Counter".
Reference
P.255 "Reset PM Counters"
Installing the Fusing Unit Maintenance
Kit
Follow these steps to install the Fus-
TKSM111N
ing Unit Maintenance Kit when
"
Limit
reached:
copy
unit
" is displayed.
counter
Important
Always make sure the free memo-
ry is 100% and turn the main pow-
er switch off before pulling out the
fixing unit. If the power is on when
you pull it out, the machine will be
damaged.
Limitation
Only pull out the fusing unit when
replacing it.
Maintaining the Machine
TKSM120N
replace
the
and
clear
the