commIssIonIng and maIntenance
dIsmantlIng accessorIes
DIVERTINg VAlVE mOTOR (STEPPER)
PRESSuRE SENSOR
NTC2 HEATINg RETuRN TEmPERATuRE SENSOR
HEATINg SAFETY VAlVE
CIRCulATOR

dIsmantlIng the exchanger

- Drain the central heating water using a connection below the lower level
of  the appliance.
- Let the appliance drain completely.
- Unscrew retaining screw "A" from the exchanger.
A
- Dismantle the electric connections from the burner, as well as the NTCs.
- Dismantle the inlet and outlet hydraulic couplings by removing the pins.
Use caution while disassembling: residual water may escape from
the  exchanger.
- Disassemble the condensate trap connection and disassemble the retaining
screw situated between the condensate trap and the exchanger.
- Lift the complete exchanger assembly vertically.
The exchanger detaches from the retaining bracket and is free to remove.
- Check the condition of the O-Rings and replace them if necessary.
Reassemble the exchanger using the same procedure in reverse order.

cleanIng the exchanger

- Dismantle the burner previously described.
- Remove the burner insulation.
- Use a vacuum cleaner to clean out the chamber.
- Disconnect the chimney from the exchanger.
- Check to see if the condensate collector is dirty and clean if necessary.
- Check the burner's insulation and seal. Replace if necessary.
- Check the electrode and replace if necessary.
- Reassemble the burner and check for any leaks.
- Switch the appliance on again. Set to maximum power mode and
check  for  leaks.
- Check the gas pressure and the CO
previous  section.