InstallatIon InstructIons
InstallatIon area
- Make sure that all air vents are unobstructed at all times.
- Do not store any flammable products in the boiler room.
- Do not store any corrosive materials, paint, solvents, salts, chlorine products
or any other detergent products in the vicinity of this appliance.
- If you smell gas, do not operate electrical switches, close the gas valve on
the meter, ventilate the rooms and contact your installer.
- The area around the boiler must be clean and free from dust.
In case of works (boiler area or near the external air inlet)
please switch off the boiler, so as to avoid the accumulation of
dust in the combustion system.
ACCESSIBIlITY
The appliance must be placed in such a way that it is always easily accessible.
Furthermore, the unit must have the following minimum clearance around  it.
Min. 25 mm

wall mountIng

- The boiler must be mounted on a non-flammable wall.
- Drill two holes with a depth of 75 mm using a 10 mm drill bit, following the
spacing given below.
- Fasten the wall mount using the supplied anchor screws.
- Attach the boiler to the wall mount.
53,2 mm
48,4 mm
101,6 mm
Min. 25 mm
101,6 mm
48,4 mm
53,2 mm
EN • 15
664Y4200 • F