Connecting Sources To The Processor; Processor Setup - Meridian DVP1080MF User Manual

Table of Contents

Advertisement

• Press < or > to select one of the following
SET: ACTIVE OUTPUT / ANALOG RGB + DVI
SET: ACTIVE OUTPUT / ANALOG RGB
• Press Menu to return to the USER MENU
Or:
• You have selected RGB on the IR remote; press YCrCb on the IR remote.
• A Component HDTV (YPrPb) output format has been connected to the PASS-THRU
(VGA) input. However, the connection from the DVP-1080 to the display is via RGBHV
out or MONITOR out.
• Connect the HDTV (YPrPb) output signal to the Component input on the DVP-1080
processor.
• Connect a Component (YPrPb) to RGBHV Transcoder between the HDTV source and the
analogue PASS-THRU input on the DVP-1080 processor.
Note: A transcoder converts an analogue YPrPb signals into an RGBHV signal
• Verify that the output/input cable(s) have not been swapped.
• Verify continuity of cable terminations.
Connecting sources to the processor
Can the DVP-1080 process computer signals sent to the DVI
INPUT or PASS-THRU input?
No. The DVP-1080 will only route a digital or analogue computer signal directly to the
pass-through circuitry.
Analogue (VGA)
When an analogue computer source is connected to the PASS-THRU input, you must
connect an RGBHV cable to the display device. The processor will not convert an analogue
VGA signal to DVI; the display device must also be capable of the resolution selected on
the computer source.
Digital (DVI)
When a digital computer source is connected to the DVI INPUT, you must connect a DVI
cable to the display device. The processor will not convert a digital DVI computer source to
RGBHV; the display device must also be capable of the resolution selected on the computer
source.
There is no video from the output when the source is connected
to the PASS-THRU input
The D-15 PASS-THRU input will only route RGBHV or YPrPb (Component) signals to pass-
through via the ANALOG OUTPUTS of the DVP-1080 (Analogue IN = Analogue OUT). It is
always recommended to install both an RGBHV cable and a DVI cable to the display device
for system expandability.
If the display does not have an RGBHV, or D-15 (VGA) input connection, install a 3-wire
Component analogue cable to the display; however, only 480i, 480p, 720p and 1080i are
valid Component video signals.
Processor setup
I changed the output scanrate, but the processor did not register
the scanrate selection
Changing the output scanrate requires confirmation of the new output scanrate selection.
Do not select an output scanrate which exceeds display device capabilities (refer to display
device User's Manual).
• Enter the SETUP MENU by pressing Menu on the IR remote for seven seconds
• Front Panel LCD display will indicate SET: NTSC SCANRATE and the current
RESOLUTION below
• Press < or > on the IR remote to select the appropriate output scanrate
• Press Store on the IR remote
• Front Panel LCD display will indicate ARE YOU SURE?
• Press Store to confirm resolution selection.
 
T r o u b l e s h o o t i n g

Advertisement

Table of Contents
loading

Table of Contents