Digital Access Keypad Manual
User Operation for the SK-1011-SQ
1. Using the User Codes:
A. User codes operate the door (4-8 digits long).
Press
u u u u
B. The
#
key must also be pressed if he keypad is in manual-entry mode.
Press
u u u u
#
2. Using the Master Code:
The Master Code can be used to operate the door or program the keypad
(4-8 digits long, see pt. 4 below).
A. To operate the relay output:
#
1
Press
X X X X
B. Inhibit/lockout code:
#
2
Press
X X X X
3. Using the Inhibit/Lockout Code:
A. Inhibit/lockout codes temporarily lock the keypad. (4-8 digits long, see pg. 5 for more information)
n n n n
Press
B. The
#
key must be pressed also if he keypad is in manual-entry mode.
Press
#
n n n n
4. User Code and Master Code Programming:
A. Enter the Master Code first, followed by the
(If you forgot the master code, see page 7 for more information.)
*
Press
X X X X
B. Change/Add/Delete User or Master Codes:
Press
1
00-99 (user ID)
u u u u
(user code, 4-8 digits)
C. Deleting Individual Users:
Press
00-99 (user ID)
#
1
D. Changing the Master Code:
Press
0
X X X X
#
*
E. To exit programming mode, press the
key.
This SECO-LARM product is warranted against defects in material and workmanship while
LIFETIME LIMITED WARRANTY
used in normal service for the lifetime of the product. SECO-LARM's obligation is limited to the repair or replacement of any defective part
if the unit is returned, transportation prepaid, to SECO-LARM. Under no circumstances will SECO-LARM be responsible for any costs or
charges for removal, installation, or reinstallation. This Warranty is void if damage is caused by or attributed to acts of God, physical or
electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason
SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and
workmanship. The sole obligation of SECO-LARM, and the purchaser's exclusive remedy, shall be limited to repair or replacement only, at
SECO-LARM's option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property
damages of any kind to the purchaser or anyone else. This lifetime limited warranty is for products sold and installed in the United States
and Canada. For all other countries the warranty is 1 (one) year.
The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM
NOTICE:
policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without
notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2010 SECO-LARM U.S.A., Inc. All rights
reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
®
SECO-LARM
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Page 8
Note:
n n n n
the inhibit code.
Note:
u u u u
the user code.
Note:
X X X X
the master code.
*
key
#
Website: www.seco-larm.com
E-mail: sales@seco-larm.com
SECO-LARM U.S.A., Inc.
ENFORCER
indicates
indicates
indicates
Also available from SECO-LARM:
Indoor Keypad
SK-1131-SQ
®
PIHAK1
SECO-LARM
®
MiSK-1011-SQ_092810.pmd
Note: Model numbers that end with "Q" or that have a round green "Q" sticker signify RoHS-compliant products.
SK-1011-SQ
Digital Access Keypad
with 5A Relay Output
MANUAL
Outdoor Keypads
SK-1123-SQ
SK-1123-FQ
SK-2323-SDQ
®
®
SK-1323-SDQ

Advertisement

loading

Summary of Contents for SECO-LARM Enforcer SK-1011-SQ

  • Page 1 Digital Access Keypad Manual ENFORCER User Operation for the SK-1011-SQ ® Note: indicates n n n n 1. Using the User Codes: the inhibit code. A. User codes operate the door (4-8 digits long). Note: u u u u indicates Press u u u u the user code.
  • Page 2: Unique Features

    Digital Access Keypad Manual Digital Access Keypad Manual REPROGRAM THE KEYPAD (CERTAIN DATA) TABLE OF CONTENTS To change certain data in the keypad (such as to delete or change user codes), do the following: Introduction ........................ 1. Enter program mode by keying in the master code and the key: Unique features ......................
  • Page 3: Specifications

    Digital Access Keypad Manual Digital Access Keypad Manual INSTALLER PROGRAMMING SPECIFICATIONS: These functions should only be used by professional installers, as incorrect entries can disable the entire keypad function. Power: Enter Programming Mode (DEFAULT: • Operation voltage -- 12-24 Volts AC/DC. No jumper needed to set voltage. 0 0 0 0 Enter Master code Confirm...
  • Page 4 Digital Access Keypad Manual Digital Access Keypad Manual USER PROGRAMMING PREPARING TO PROGRAM THE KEYPAD Before programing the SK-1011-SQ, you will need to first determine the following information: Enter Programming Mode Enter Master code Confirm Function 1. The master code -- Allows the system administrator to program or operate the keypad. X X X X Enter into programming mode Note:...