External Control
Table 6-1. Serial Commands (continued)
Parameter
Command
IHEIGHT
0/20
IHEIGHT?
NA
IHPOS
-50/50
IHPOS?
NA
IVPOS
-50/50
IVPOS?
NA
IWIDTH
0/50
IWIDTH?
NA
OVERSCAN
OVERSCAN?
NA
OVERSCANMODE
OVERSCANMODE?
NA
OHEIGHT
-50/50
OHEIGHT?
NA
OHPOS
-50/50
OHPOS?
NA
OVPOS
-50/50
OVPOS?
NA
OWIDTH
-50/50
OWIDTH?
NA
Value
(min/max)
Stored?
Input Position Commands
YES
NA
YES
NA
YES
NA
YES
NA
0/20
YES
NA
0/1
YES
NA
Output Shift Commands
YES
NA
YES
NA
YES
NA
YES
NA
90
Runco VX-44d/-55d Installation/Operation Manual
Description
Sets the value for input height
Returns input height value
Sets a value for horizontal input position
Returns input horizontal position value
Sets a value for vertical input position
Returns input vertical position value
Sets the value for input width
Returns input horizontal width value
Sets the overscan percentage
Returns overscan percentage
Sets the overscan mode (0=zoom;
1=crop)
Returns the overscan mode (0=zoom;
1=crop)
Sets the value for output height
Returns output height value
Sets the value for output horizontal posi-
tion
Returns output horizontal position value
Sets the value for output vertical position
Returns output vertical position value
Sets the value for output width