(2) Function setting list
Forthedetailsoftheitems,refertotheInstructionManualforSC-90.
* DDL-8700 is given as an example here. However, initial value changes according to the machine head to be
connected.
No.
Item
Softstartfunction Thenumberofstitchestobesewnatalowspeedwhenthesoft-
startfunctionisusedatthestartofsewing.
0:Soft-startfunctionisnotoperative.
5
Flickerreducing
Flicker reducing function (If the hand lamp flickers).
function
0:Flickerreducingfunctionisnotoperative.
:Lesseffective/8:Highlyeffective
6
Bobbinthread
Bobbinthreadcountingfunction
countingfunction
0:Bobbinthreadcountingfunctionisnotoperative.
:Bobbinthreadcountingfunctionisoperative.
7
Bobbinthread
Unitofbobbinthreadcountingdown
countunit
0:Count/0stitches
:Count/5stitches
2:Count/20stitches
8
Numberof
Sewingspeedofreversefeedstitching
rotationofreverse
feedstitching
0
Settingofneedle
Position of needle bar is specified when the sewing machine stops.
barstopposition
0:Predeterminedlowestposition
whenthesewing
:Predeterminedhighestposition
machinestops.
Clicksoundofkey
Click sound of key switch mounted on PSC is specified.
switchmounted
0:Clickisnotoperative.
onPSC
:Clickisoperative.
2
Optinalswitch
Switchingoffunctionofoptionalswitch.
functionselection
0:Nofunction
:Needleup/downcompensatingstitching
2:Backcompensatingstitching
3:Functionofcancelingoncereversefeedstitchingatthe
endofsewing
4:Threadtrimmingfunction
5:Presserfootliftingfunction
6:Onestitchcompensatingstitching
7:Functionofsimultaneouslycancelingreversefeed
stitchingatthestartandendofsewing
8:Functionofneutralpresserfootliftingchangeover
3
Functionof
Function of prohibiting start of the sewing machine by bobbin
prohibitingstart
threadcounting
ofthesewing
0:Whencountingisout(-orless)Functionofprohibiting
machineby
startofthesewingmachineisnotoperative.
bobbinthread
:Whencountingisout(-orless)Functionofprohibiting
counter
startofthesewingmachineafterthreadtrimmingisoperative.
2:Whencountingisout(-orless),thesewingmachine
stopsonce.Functionofprohibitingstartofthesewing
machineafterthreadtrimmingisoperative.
4
Sewingcounter
Countingfunctionofsewing(numberofcompletionofprocess)
0:Sewingcounterfunctionisnotoperative.
:Sewingcounterfunctionisoperative.
5
Numberoftimes
Numberoftimesofdetectionofrun-outofbobbinthreadremaining
ofdetectionof
amount
run-outofbobbin
0: F unctionofbobbinthreadremainingamountisnotoperative.
threadremaining
to9: N umberoftimesduringwhichthesignalisnotmadeeven
amount
ifrun-outofbobbinthreadremainingamountisdetected.
7
Keylockfunction
Keylockfunction
0:Withoutkeylock
:Withkeylock
Description
–32–
Paneldisplay
Setting
Setting
Standardset
level
range
value
N-SOFT
0to9
T-ACC
2
0to8
SCBOB
0to
RATIO
0to2
50to
S-BT
3000
500
2
0to
SOUND
2
0to
SW2
2
0to8
ASCNT
2
0to2
NTO
2
0to
BTDS
2
0to9
KEYLOCK
2
0to
0
0
NPS
0
0
0
0