Thread Tension Release Changeover When Using The Knee Lifter; One-Touch Manual Reverse Feed (One-Touch Reverse Feed Type) - JUKI LH-3500 Series Instruction Manual

Lh-3500 series
Table of Contents

Advertisement

5-5. Thread tension release changeover when using the knee lifter

5-6. One-touch manual reverse feed (One-touch reverse feed type)

[LH-3528, 3528-7, 3578-7]
・How to use
)
Press swtch 1 , and the sewng machne wll mmedately run n the reverse drecton to perform
the reverse feed sttchng.
2)
Reverse sttchng s made as long as you keep pressng the swtch.
3)
Release the swtch, and the sewng machne wll run n the normal drecton.
1
2
3
1
At the tme of delvery of LH-3568 and 3568-7,
3588, 3588-7 the knee lfter or AK devce s not
nterlocked wth the thread tenson release of
thread tenson controller. When releasng the
thread tenson, press lever 1 to rse the dsks.
• When interlocking the thread tension release
Remove the wper solenod n case of the machne
wth wper. Remove the cap at the back, loosen
screw 2 , move screw 2 n the drecton of arrow
up to the end of slot of lftng lnk 3 , and fix it.
When interlocking the thread tension
release :
1. Thread slacks when turning cloth at the
corner stitching, and sewing trouble of
thread tension release may occur .
2. When the wiper is not used at the time
of thread trimming, needle thread may
be drawn out when removing cloth.
3. Just loosen screw 2 , and do not
remove it.
[LH-3568, 3588-7]
1
– 27 –