Configuring Online Diagnostics
Command
Step 4
diagnostic monitor threshold switch
number test {name | test-id |
test-id-range | all} failure count count
Step 5
diagnostic monitor switch number test
{name | test-id | test-id-range | all}
Step 6
end
Step 7
show diagnostic {content | post | result
| schedule | status | switch}
Step 8
show running-config
Step 9
copy running-config startup-config
To disable diagnostic testing and return to the default settings, use these commands:
This example shows how to configure a health-monitoring test:
Switch(config)# diagnostic monitor threshold switch 3 test 1 failure count 50
Switch(config)# diagnostic monitor interval switch 3 test TestPortAsicRingLoopback
Cisco Catalyst Blade Switch 3120 for HP Software Configuration Guide
48-4
Purpose
(Optional) Set the failure threshold for the health-monitoring tests.
The range for the switch number keyword is from 1 to 9.
When specifying the tests, use one of these parameters:
The range for the failure threshold count is 0 to 99.
Enable the specified health-monitoring tests.
The range for the switch number keyword is from 1 to 9.
When specifying the tests, use one of these parameters:
Return to privileged EXEC mode.
Display the online diagnostic test results and the supported test suites. See
the
page 48-6
Verify your entries.
(Optional) Save your entries in the configuration file.
To disable online diagnostic testing, use the no diagnostic monitor switch number test {name |
test-id | test-id-range | all} global configuration command.
To return to the default health-monitoring interval, use the no diagnostic monitor interval switch
number test {name | test-id | test-id-range | all} global configuration command.
To configure the switch to not generate a syslog message when the health-monitoring test fails, use
the no diagnostic monitor syslog global configuration command.
To return to the default failure threshold, use the no diagnostic monitor threshold switch number
test {name | test-id | test-id-range | all} failure count count global configuration command.
name—Name of the test that appears in the show diagnostic content
command output.
test-id—ID number of the test that appears in the show diagnostic
content command output.
test-id-range—ID numbers of the tests that appear in the show
diagnostic content command output.
all—All of the diagnostic tests.
name—Name of the test that appears in the show diagnostic content
command output.
test-id—ID number of the test that appears in the show diagnostic
content command output.
test-id-range—ID numbers of the tests that appear in the show
diagnostic content command output.
all—All of the diagnostic tests.
"Displaying Online Diagnostic Tests and Test Results" section on
for more information.