Event Codes versus Maintenance Action (Continued)
Table 3-3
Event
Code
Explanation
583
Loss of signal or loss of synchronization.
584
Not operational primitive sequence received.
585
Primitive sequence timeout.
586
Invalid primitive sequence received for current link state.
810
High temperature warning (CTP thermal sensor).
811
Critically hot temperature warning (CTP thermal sensor).
812
CTP card shutdown due to thermal violations.
850
Switch shutdown due to CTP thermal violations.

MAP 0000: Start MAP

This MAP describes initial fault isolation beginning at the:
• Failed product.
• Browser-capable PC with Internet connectivity to the firmware-
resident Enterprise Fabric Connectivity Manager (EFCM) Basic
Edition interface.
• Product-attached open systems interconnection (OSI) host
console.
1
Prior to fault isolation, acquire:
A system configuration drawing or planning worksheet that
includes the location of the product, management interface,
other McDATA products, and device connections.
The internet protocol (IP) address, gateway address, and subnet
mask for the product reporting the problem.
User IDs and passwords.
Continue to the next step.
Maintenence Analysis Procedures
Action
Go to
MAP
0500.
Go to
MAP
0500.
Go to
MAP
0500.
Go to
MAP
0500.
Go to
MAP
0400.
Go to
MAP
0400.
Go to
MAP
0400.
Go to
MAP
0400.