Map 400 Event Codes - McDATA Sphereon 4300 Installation And Service Manual

Fabric switch
Hide thumbs Also See for McDATA Sphereon 4300:
Table of Contents

Advertisement

MAP 400 Event Codes

Table 3-6
Event
Explanation
Code
300
Cooling fan propeller failed.
301
Cooling fan propeller failed.
302
Cooling fan propeller failed.
370
Cooling fan status polling temporarily disabled.
426
Multiple ECC single-bit errors occurred.
433
Non-recoverable Ethernet fault.
440
Embedded port hardware failed.
810
High temperature warning (CTP thermal sensor).
811
Critically hot temperature warning (CTP thermal sensor).
812
CTP card shutdown due to thermal violations.
850
Switch shutdown due to CTP thermal violations.
2
Visual inspection or event code 300, 301, or 302 indicates one or
more cooling fans failed. Replace the switch. Exit MAP.
3
As indicated by event code 370, cooling fan status polling is
temporarily disabled and status values for one or more fans exceed a
set threshold. This indicates possible fan degradation or failure.
Is this event code a recurring problem?
NO
YES
A fan failure is indicated. Go to
Monitor fan operation or recording of additional failure event codes.
Exit MAP.
Maintenence Analysis Procedures
Action
Go to
Go to
Go to
Go to
Go to
Go to
Go to
Go to
Go to
Go to
Go to
step
2.
Maintenance Analysis Procedures
step
2.
step
2.
step
2.
step
3.
step
4.
step
5.
step
5.
step
6.
step
6.
step
6.
step
6.
3-15