Event Code: 581
Message:
Implicit incident.
Severity:
Major.
Explanation:
An attached server recognized a condition caused by an event that occurred at the server. The event caused an
implicit Fibre Channel link incident.
Action:
A link incident record (LIR) is generated and sent to the attached server using the reporting procedure defined in
T11/99-017v0 (OSI). If fault isolation at the server does not detect a failure, the problem may be due to a port
failure. Go to
MAP 0000: Start MAP
CD to support personnel.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Product
EFCM Basic
Event Log
Event Code: 582
Message:
Bit error threshold exceeded.
Severity:
Major.
Explanation:
An attached server determined the number of code violation errors recognized exceeded the bit error threshold.
Action:
A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI).
If fault isolation at the server does not detect a failure, the problem may be due to a port failure. Go to
Start MAP
to perform fault isolation. In addition, perform a data collection and return the CD to support personnel.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Product
EFCM Basic
Event Log
to perform fault isolation. In addition, perform a data collection and return the
Management Server
System
Event Log
Error LED
Management Server
System
Event Log
Error LED
E-Mail
Call-Home
Sense Info
E-Mail
Call-Home
Sense Info