Normal Operating Sounds Of Gas Appliances; Thermopile/Thermocouple; Maintenance; Maintenance Instructions - Regency C34-LP2 Owners & Installation Manual

C34 series classic direct vent freestanding gas stove
Table of Contents

Advertisement

MAINTENANCE

NORMAL OPERATING
SOUNDS OF
GAS APPLIANCES
It is possible that you will hear some sounds
from your gas appliance. This is perfectly nor-
mal due to the fact that there are various gauges
and types of steel used within your appliance.
Listed below are some examples. All are nor-
mal operating sounds and should not be
considered as defects in your appliance.
Blower:
Regency gas appliances use high tech blowers
to push heated air farther into the room. It is not
unusual for the fan to make a "whirring" sound
when ON. This sound will increase or decrease
in volume depending on the speed setting of
your fan speed control.
Burner Tray:
The burner tray is positioned directly under the
burner tube(s) and logs and is made of a
different gauge material from the rest of the
firebox and body. Therefore, the varying thick-
nesses of steel will expand and contract at
slightly different rates which can cause "tick-
ing" and "cracking" sounds. You should also be
aware that as there are temperature changes
within the unit these sounds will likely re-occur.
Again, this is normal for steel fireboxes.
Blower Thermodisc:
When this thermally activated switch turns ON
it will create a small "clicking" sound. This is the
switch contacts closing and is normal.
Pilot Flame:
While the pilot flame is on it can make a very slight
"whisper" sound.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.
30
THERMOPILE/
THERMOCOUPLE
1) Loosen the thermocouple or thermopile with
a 7/16" wrench at bracket.
2) Disconnect thermocouple by loosening nut
from the valve with a 9mm wrench. Discon-
nect thermopile by loosening 2 screws
marked TP on the valve.
3) Drop the thermocouple or thermopile down
from the bracket and pull it out of the unit.
4) Reinstall the new ones in reverse order.
MAINTENANCE
INSTRUCTIONS
1) Always turn off the gas valve before clean-
ing. For relighting, refer to lighting instruc-
tions. Keep the burner and control compart-
ment clean by brushing and vacuuming at
least once a year.
When cleaning the logs, use a soft clean
paint brush as the logs are fragile and easily
damaged.
2) Clean appliance and door with a damp cloth
(never when unit is hot). Never use an
abrasive cleaner.
The heater is finished in a heat resistant
paint and should only be refinished with
heat resistant paint. Regency uses Stove
Brite Paint - Metallic Black #6309.
3) The glass should be cleaned with a gas
fireplace glass cleaner when it starts to turn
milky.
4) Make a periodic check of burner for proper
position and condition. Visually check the
flame of the burner periodically, making sure
the flames are steady; not lifting or floating.
If there is a problem, call a qualified service
person.
5) The appliance and venting system must be
inspected before use, and at least annually,
by a qualified field service person, to ensure
that the flow of combustion and ventilation
air is not obstructed.
During the annual service call, the burners
should be removed from the burner tray and
cleaned. Replace the embers and rock wool.
6) Keep the area near the appliance clear and
free from combustible materials, gasoline
and other flammable vapours and liquids.
CAUTION:
ANY SAFETY SCREEN OR GUARD
REMOVED FOR SERVICING AN
APPLIANCE MUST BE REPLACED
PRIOR TO OPERATING THE AP-
PLIANCE.
NEVER OPERATE THE APPLIANCE
WITHOUT THE GLASS PROPERLY
SECURED IN PLACE.
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system
semiannually. Recommended areas to inspect
are:
1) Check areas of the Venting System which
are exposed to the elements, for corrosion.
These will appear as rust spots or streaks,
and in extreme cases, holes. These compo-
nents should be replaced immediately.
2) Remove the Cap, and shine a flashlight
down the Vent. Remove any birds nests, or
other foreign material.
3) Check for evidence of excessive conden-
sation, such as water droplets forming in
the inner liner, and subsequently dripping
out the joints, Continuous condensation
can cause corrosion of caps, pipe, and
fittings. It may be caused by having exces-
sive lateral runs, too many elbows, and
exterior portions of the system being ex-
posed to cold weather.
4) Inspect joints, to verify that no pipe sections
or fittings have been disturbed, and conse-
quently loosened. Also check mechanical
supports such as Wall Straps for rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the
logs. The pilot light generates enough heat to
burn someone. If for any reason a log should
need replacement, use only Regency replace-
ment logs. The position of these logs must be as
shown in the diagram under Log Installation.
Note: Improper positioning of logs may
create carbon buildup and will al-
ter the unit's performance which
is not covered under warranty.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C34-ng2

Table of Contents