2. Auxiliary Codes A-2 and Later

This icemaker must be cleaned and sanitized at least twice a year. More frequent
cleaning and sanitizing may be required in some water conditions.
• To prevent injury to individuals and damage to the icemaker, do not use ammonia
type cleaners.
• Carefully follow any instructions provided with the bottles of cleaning and
sanitizing solution.
• Always wear liquid-proof gloves and goggles to prevent the cleaning and sanitizing
solutions from coming into contact with skin or eyes.
• Do not use ice made from the cleaning and sanitizing solutions. After cleaning and
sanitizing, be careful not to leave any solution in the icemaker.
a) Cleaning Solution
Dilute 1.6 fl. oz. (47 ml or 3.2 tbs) of Hoshizaki "Scale Away" with 1 qt. (1 l) of warm water.
This is a minimum amount. Make more solution if necessary. IMPORTANT! For safety
and maximum effectiveness, use the solution immediately after dilution.
b) Cleaning Procedure
1) Move the power switch to the "OFF" position, then unplug the unit from the electrical
outlet. WARNING! To reduce the risk of electric shock, do not touch the power
switch or plug with damp hands.
2) Close the water supply line shut-off valve.
3) While maintaining a hold on the door, remove the hinge stop pin from hinge (B). Pull out
the bottom of the door slightly, then gently remove the door from hinge (A). See Fig. 15.
4) Remove the 2 screws securing the top panel, then lift it off.
Top Panel
Scoop
Holder
Slope
Hinge (B)
Hinge Stop Pin
Fig. 15
WARNING
Hinge (A)
Float Switch
Assembly
Reservoir
Cover
Reservoir
Reservoir
Hose
Evaporator
Assembly
Overflow
Hose
54
Spout
Packing
Extruding
Head
Drain Plug
Drain Clamp
Drain Hose
Upper Rear Panel