NATURAL GAS - VENTING WITH ONE 90° ELBOW
V (FT.)
1' MIN. (305mm)
2' MIN. (610mm)
3' MIN. (914mm)
4' MIN. (1.22m)
5' MIN. (1.5m)
6' MIN. (1.83m)
V + H = 50' MAX.
(15.2m)(11.3m)
PROPANE - VENTING WITH ONE 90° ELBOW
V (FT.)
1' MIN. (305mm)
2' MIN. (610mm)
3' MIN. (914mm)
4' MIN. (1.22m)
5' MIN. (1.5m)
6' MIN. (1.83m)
V + H = 50' MAX. (15.2m)
Figure 13. Venting with One 90° Elbow
NATURAL GAS
VENTING WITH ONE 90° ELBOW
V (FT.)
0
90
Elbow on top
2.5' MAX. (64mm)
1' MIN. (305mm)
3' MAX. (914mm)
2' MIN. (610mm)
6' MAX. (1.83m)
3' MIN. (914mm)
9' MAX. (2.7m)
4' MIN. (1.22m)
12' MAX. (3.6m)
5' MIN. (1.5m)
15' MAX. (4.5m)
6' MIN. (1.83m)
18' MAX. (5.5m)
V + H = 50' MAX. (15.2m)
Figure 14. Venting with One 90° Elbow
H (FT.)
3' MAX. (914mm)
6' MAX. (1.83m)
9' MAX. (2.7m)
12' MAX. (3.6m)
15' MAX. (4.5m)
18' MAX. (5.5m)
H (FT.)
2' MAX. (610mm)
V
4' MAX. (1.22m)
6' MAX. (1.83m)
8' MAX. (2.4m)
10' MAX. (3.0m)
12' MAX. (3.6m)
VENTING WITH ONE 90° ELBOW
H (FT.)
V (FT.)
0
90
Elbow on top
1' MIN. (305mm)
2' MIN. (610mm)
3' MIN. (914mm)
4' MIN. (1.22m)
5' MIN. (1.5m)
6' MIN. (1.83m)
Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06
H
H
PROPANE
H (FT.)
2' MAX. (610mm)
2' MAX. (610mm)
4' MAX. (1.22m)
6' MAX. (1.83m)
8' MAX. (2.4m)
10' MAX. (3.0m)
12' MAX. (3.6m)
V + H = 50' MAX. (15.2m)
V
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hv-ipi qv-stIllage qv-pier hv-ipiIllage qv-st hv-ipi

Table of Contents