Commissioning:

The whole of the gas installation, including the meter,
should be inspected, purged and tested for leakage in
accordance with local codes.
1. Ensure that all controls are in the off position and
turn on the main gas supply and electrical mains.
2. Remove the screws securing the front fascia and
connect a U-gauge manometer to the pressure test
point on the main manifold. Operate the main
burners in accordance with the instructions given
in the User's manual.
3. Check that the setting pressure is correct per
TABLE C on the previous page. If necessary, adjust
the pressure governor located at the rear of the
range, downstream of the shut-off valve, to give the
required setting.

Burner Adjustments:

Griddle /Solid Hot Top Burner

Check that the aeration shutter is set to provide the
required opening per table E on the previous page. Adjust
if necessary.
SHUTTER
OPENING
MEASUREMENT

Hot Top Minimum Flame Setting

1. Set the gas tap to the LOW position.
2. Connect a U-gauge manometer to the pressure test
nipple located downstream of the gas tap.
P151 Rev. 1 (03/05)
INSTALLATION continued
FIXING SCREW
INJECTOR
LOCATION
3. With a flat screwdriver, turn the adjuster on the
body of the tap clockwise to reduce the pressure or
anti-clockwise to increase pressure. Set the pressure
to correspond with table D.

Oven Burner

1. Check that the aeration shutter is set to the required
opening per table E. Adjust if necessary.
SHUTTER
OPENING
MEASUREMENT
When all the settings have been checked, remove the U-
gauge manometer, replace the pressure test point screw
and the lower front panel.
Hand the USER's INSTRUCTIONS to the user or
purchaser for retention and instruct them in the efficient
and safe operation of the appliance.
Tell the user of the location of the gas isolation cock for
use in an emergency. Leave this Installation and Servicing
Instruction Manual with the user or purchaser.