Garland BH/IN 2500 Installation And Operation Manual

Rtcs technology built in induction cookers
Hide thumbs Also See for BH/IN 2500:

Advertisement

GARLAND RTCS TECHNOLOGY BUILT IN
MODELS: BH/IN 2500, SH/IN 3500,SH/IN 5000,
SH/WO/IN 3500,SH/WO/IN 5000 & SH/WO/IN 8000
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice.
GARLAND COMMERCIAL INDUSTRIES
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
Part # 4520898 (03/31/11)
Part # 4520898 (03/31/11)
INSTALLATION AND
OPERATION MANUAL
INDUCTION COOKERS,
86037
APPLIANCE
WARNING:
GARLAND COMMERCIAL RANGES, LTD.
1177 Kamato Road, Mississauga, Ontario L4W 1X4
CANADA
Phone: 905-624-0260
Fax: 905-624-5669
C
CM
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
INSTALLATION AND ELECTRICAL CONNECTION
MUST COMPLY WITH CURRENT CODES:
IN CANADA - THE CANADIAN ELECTRICAL
CODE PART 1 AND / OR LOCAL CODES.
IN USA – THE NATIONAL ELECTRICAL CODE
ANSI / NFPA – CURRENT EDITION.
ENSURE ELECTRICAL SUPPLY CONFORMS WITH
ELECTRICAL CHARACTERISTICS SHOWN ON
THE RATING PLATE.
© 2005 Garland Commercial Industries, Inc.
Enodis UK LTD.
Swallowfield Way, Hayes, Middlesex UB3 1DQ ENGLAND
Telephone: 081-561-0433
Fax: 081-848-0041
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Garland BH/IN 2500

  • Page 1 Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
  • Page 2 Page 2 Part # 4520898 (03/31/11)
  • Page 3: Important Information

    IMPORTANT INFORMATION The instructions in this manual are fundamentally important and must be taken into account during assembly, operation Warning and maintenance. They must therefore be read very carefully Risk of fire or electric before installation and operation by the responsible shock specialist staff and the operator(s).
  • Page 4 Page 4 Part # 4520898 (03/31/11)
  • Page 5: Table Of Contents

    Control Of The Heating Area ... . . 21 Cut Out For Model BH/IN 2500 ....9 MAINTENANCE AND CLEANING .
  • Page 6: Dimensions And Specifications

    DIMENSIONS AND SPECIFICATIONS OPERATING CONDITIONS Maximum Tolerance of +6/-10% Supply Voltage Supply Frequency 50/60 Hz Protection Class IP XO Minimal Diameter Of The Pan 4 3/4” (120mm) (BH/IN and SH/IN) Storage -4º to 158ºF (-20º to 70ºC) Maximum Ambient Temperature Function 41º...
  • Page 7: General Information

    1. Generator with built-in frame including glass top. 2. Operating unit. Product Overview Garland supplies several basic types of units with different performances and measurements. Built with a robust method of construction, they are compact and powerful with a revolutionary technology in a complete case of CrNi-steel.
  • Page 8: Installation

    Also ensure that the air of air inlet and air outlet do not mix. 3. The induction unit must not be placed next to an oven or Garland recommends guaranteeing a supply of fresh air by another heat producing unit.
  • Page 9: Cut Out For Model Bh/In 2500

    INSTALLATION continued Cut Out For Model BH/IN 2500 The size of the cut out in the built-in area must be, 11.41” x 11.41” (290 x 290mm), the depth 7.87” (200mm) and the base at least 13.39” x 11.75” (340 x 273mm).
  • Page 10: Cut Out For Models Sh/In 3500

    INSTALLATION continued Cut Out for Models SH/IN 3500 And SH/IN 5000 The size of the cut out in the built-in area must be 13.78” x 13.78” (350 x 350mm), the depth 9.45” (240mm) and the base at least 16.14” x 13.90” ( 410 x 353mm). 0.06"...
  • Page 11: Cut Out For Models Sh/Wo/In 3500, Sh/Wo/In 5000 And Sh/Wo/In 8000

    INSTALLATION continued Cut Out For Models SH/WO/IN 3500, SH/WO/IN 5000 And SH/WO/IN 8000 The size of the cut out for the built in area must be 14.37” x 14.37” (365 x 365mm), the depth 11.81” (300mm) and the base at least 16.14” x 13.90” (410 x 353mm). 0.06”...
  • Page 12: Unit Placement

    INSTALLATION continued Unit Placement Installation of Operating Unit After the cut out has been made according to the previous Each unit is supplied with a complete operating unit. In order sections, apply silicone to the top of the counter and press to fix this unit on the surface of the enclosure, a cut out for the induction unit into the silicone, allowing for a complete the power switch and the LED must considered.
  • Page 13: Fresh Air Intake Installation

    INSTALLATION continued Figure # 1 Cut Out Opening Silicone Louvered Air Exhaust Opening (By Installer) Sleeve with hose clip: mounted on bottom of unit Aluminum air duct (Max 96" (8')) Sleeve with hose clip: mounted on collars mounted to cabinet with hose clamps Removable grease lter and air intake housing mounted on...
  • Page 14: Instructions For Assembly

    As soon as the above mentioned preparations are made, the completely pre-mounted induction unit can be installed into Garland has made enhancements for the installation the counter. Apply silicone, which is provided with every air requirements for the induction cooker built-in models. These...
  • Page 15 Part # 4520898 (03/31/11) Page 15...
  • Page 16 Page 16 Part # 4520898 (03/31/11)
  • Page 17 Part # 4520898 (03/31/11) Page 17...
  • Page 18 Page 18 Part # 4520898 (03/31/11)
  • Page 19: Electrical Installation

    INSTALLATION continued Electrical installation 1 Put some water in the pan and place it in the center of the heating area. If the voltage is wrong, the 2. Turn the control knob to an ON position. The indicator CAUTION cooker can be damaged. will light up (green) and the water will be heated.
  • Page 20: Operation

    OPERATION Cooking Process Safety Concerns Risk Involved By Disregarding Safety Information The induction cooker is switched on by turning the control ➯ knob (OFF ON) and it is immediately ready for operation. Danger for persons, the environment and the cooker as The luminous operation indicator light means that energy well as claims for damages of any kind can result from is being transferred to the pan.
  • Page 21: Unauthorized Reconstruction And Use Of Spare Parts

    OPERATION continued Unauthorized Reconstruction • Since metallic objects are heated up very quickly when placed on the heating area, do not place any other And Use Of Spare Parts objects (closed cans, aluminium foil, cutlery, jewelry, watches etc.) on the induction cooker. Reconstruction of the cooker or changes to the cooker are not allowed.
  • Page 22: Maintenance And Cleaning

    MAINTENANCE AND CLEANING NOTE: ensure no liquid can enter the induction unit, do Ceran glass not clean the cooker with a jet of water . 1. The cleaning of the Ceran glass is identical to other Cleaning similar surfaces like glass. Do not use corrosive or abrasive cleaning agents, such as grill- and oven-sprays, stain- and Slight soiling, no burned residues rust-removers, scouring powder and rough sponges.
  • Page 23: Malfunction With Error Code

    TROUBLESHOOTING continued Malfunction With Error Code Number of Flashing Possible Cause Action To Take By Operator Or Operating Signals (Code) Personnel Overheated heat sink Let unit cool down - . . . - . . . Check air filter and air flow Air-cooling system obstructed Verify that air inlet and air outlet are not obstructed with objects...
  • Page 24: Malfunction Without Error Code

    TROUBLESHOOTING continued Malfunction Without Error Code Fault Possible Cause Action To Take By Operator Or Operating Personnel No heating No mains supply Check the electrical supply (cable plugged Operation indicator light onto the wall socket) is OFF (dark) Check preliminary fuses Control knob is in OFF-position Turn control knob ON Cooker is defective...
  • Page 25 TROUBLESHOOTING continued Fault Possible Cause Action To Take By Operator Or Operating Personnel After a long permanent Coil overheated, cooking area too hot Switch cooker off, remove pan and wait until operating time, the Empty pan the cooking area has cooled off heating switches off and Pan with overheated oil on within minutes...
  • Page 26 Page 26 Part # 4520898 (03/31/11)
  • Page 27 Part # 4520898 (03/31/11) Page 27...

This manual is also suitable for:

Sh/wo/in 5000Sh/wo/in 8000Sh/wo/in 3500

Table of Contents