B. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm)
the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a
DVP-HSM-B will be required.
15-1/8 in.
(384 mm)
12 in.
(305 mm)
SLK-SNKD
Termination Cap
Figure 16.8 SLP Series Vent Components
66
8 in.
(203 mm)
SLP-TRAP
Horizontal Termination Cap
Snorkel
Support Box-Black
DVP-2SL
Adapter
SLP-DCF-BK
Ceiling Firestop
Black
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13
Heat
Shield
Term Cap
Max
Effective
Length
SLP-CCS-BK
Cathedral Ceiling
Extended Heat Shield
SLP-WT-BK
Wall Thimble-Black
Minimum
Effective Length
Effective Length
3-1/8 in.
Trap1
79 mm
5-1/4 in.
Trap2
133 mm
SLP-TVHW
Vertical
Termination Cap
26 in.
660 mm
DVP-HSM-B
Maximum
4-3/4 in.
121 mm
9-1/4 in.
235 mm