Accessory; Concentric Vent - Payne PG9MAA Specification

Multipoise condensing gas furnace
Hide thumbs Also See for PG9MAA:
Table of Contents

Advertisement

COMBUSTION-AIR
PIPEFORNON-DIRECT VENT
APPLICATIONS
(Sizes 040 through
120 only)
._ FIELD-SUPPLIED
2-IN.
DIAMETER
r-
FIELD-SUPPLIED
PVC 90' ELBOW//
2-IN.
DIAMETER
_"
PVC
PIPE
U-FA-
_COMBUSTION-AIR
DISC
(FACTORY-SUPPLIED
IN
LOOSE
PARTS
BAG)
A96211
LENGTH OF STRAIGHT PIPE PORTION OF
COMBUSTION-AIR
INLET PIPE ASSEMBLY
(IN.)
CASING
WIDTH
A
17-1/2
8-1/2 + 1/2
21
10-I/2
+ I/2
24-1/2
12 + 1/2
ACCESSORIES
CONCENTRIC VENT
(Direct Vent Applications
Only)
B IN. DIA PVC
VENT/EXHAUST
I
---
: ....
:_
,-
._D,.. 11/2_._
_I3/_16
"_
l
L
C IN. DIA
_
D "_J"
A
--B
IN. DIA PVC
INTAKE/COMBUSTION
AIR
A97110
Note:
See furnace
Installation
Instructions
when
venting
multiple
furnaces
near each
other.
DIMENSIONS (In.)
PART NO.
A*
B
C
Dt
E
F
KGAVTO50ICVT
33-3/8
2
3-I/2
16-5/8
6-I/4
5-3/4
KGAVT060ICVT
38-7/8
3
4-I/2
2I-1/8
7-3/8
6-1/2
* Dimension
A will change
accordingly
as dimension
D is lengthened
or shortened.
1- Dimension
D may be lengthened
to 60 in. maximum.
Dimension
D may also be shortened
by cutting
the pipes provided
in the kit to 12 in. minimum.
i12i