Combustion Air - Payne PG9MAA Specification

Multipoise condensing gas furnace
Hide thumbs Also See for PG9MAA:
Table of Contents

Advertisement

COMBUSTION-AIR
AND VENT PIPING FOR DIRECT VENT (2 PIPE) APPLICATIONS
ALTITUDE
ABOVE
SEA
LEVEL
(FT)
0 to 2000
200I
to 3000
300I
to 4000
MAXIMUM ALLOWABLE
PIPE LENGTH (FT)
UNIT SIZE
024040
036040
024060
036060
048060
036080
048080
060080
048100
060100
060120
060140
024040
036040
024060
036060
048060
036080
048080
060080
048100
060100
060120
060140
024040
036040
024060
036060
048060
036080
048080
060080
048100
060100
060120
060140
TERMINATION
TYPE
2 Pipe or 2-in. Concentric
2 Pipe or 2-in. Concentric
2 Pipe or 2-in. Concentric
2 Pipe or 3-in. Concentric
2 Pipe or 3-in. Concentric
2 Pipe or 3-in. Concentric
2 Pipe or 2-in. Concentric
2 Pipe or 2-in. Concentric
2 Pipe or 2-in. Concentric
2 Pipe or 3-in. Concentric
2 Pipe or 3-in. Concentric
2 Pipe or 3-in. Concentric
2 Pipe or 2-in. Concentric
2 Pipe or 2-in. Concentric
2 Pipe or 2-in. Concentric
2 Pipe or 3-in. Concentric
2 Pipe or 3-in. Concentric
2 Pipe or 3-in. Concentric
PIPE
DIAMETER
(IN.)*
1
I-1/2
2
I-1/2
2
I-1/2
2
2-1/2
2
2-1/2
3
2-1/2 one disk
31-
31-no disk
2-1/2 one disk
31-one disk
31-no disk
41-no disk
I-1/2
2
I-1/2
2
2
2-I/2
2-1/2
3
3
31-no disk
41-no disk
31-one disk
31-no disk
41-no disk
I-1/2
2
I-1/2
2
2
2-/12
2-1/2
3
31-no disk
41-no disk
31-one disk
31-no disk
41-no disk
1
5
7O
7O
2O
7O
I0
55
7O
5
4O
7O
I0
45
7O
5
4O
6O
7O
67
7O
I7
7O
49
7O
35
7O
I4
7O
7O
2O
39
7O
64
7O
I6
68
46
7O
33
7O
65
7O
I1
3O
7O
2
NA
7O
7O
I5
7O
NA
5O
7O
NA
3O
7O
NA
4O
7O
NA
35
56
7O
62
7O
I2
67
44
7O
26
7O
9
7O
7O
I5
35
7O
59
7O
I1
63
41
7O
24
7O
58
7O
6
26
7O
NUMBER
OF 90 °
3
NA
65
70
10
70
NA
35
70
NA
20
70
NA
35
70
NA
30
52
70
57
70
7
66
30
70
16
70
NA
63
70
10
3I
70
54
70
6
62
28
70
15
70
5I
70
NA
22
70
ELBOWS
4
NA
60
70
5
70
NA
30
70
NA
20
70
NA
30
70
NA
25
48
70
52
70
NA
6I
25
70
16
70
NA
56
70
5
27
70
49
70
NA
57
23
70
14
66
44
70
NA
18
70
5
NA
6O
7O
NA
7O
NA
3O
7O
NA
10
7O
NA
25
7O
NA
2O
44
7O
52
7O
NA
6I
25
7O
6
66
NA
50
7O
NA
23
7O
48
7O
NA
57
22
7O
5
6I
38
7O
NA
14
7O
6
NA
55
7O
NA
7O
NA
2O
7O
NA
NA
7O
NA
2O
7O
NA
I5
4O
7O
47
7O
NA
61
I5
7O
NA
61
NA
43
7O
NA
I9
7O
43
7O
NA
56
I3
7O
NA
56
31
7O
NA
I0
7O
* Disk usage--Unless
otherwise
s _ecified, use perforated
disk assembly
(factory-supplied
in loose parts bag). If one disk is stated, separate
2 halves of per-
forated
disk assembly
and use shouldered
disk half. When
using shouldered
disk half, install screen
side toward inlet box.
1- Wide radius elbow.
_: Vent sizing for Canadian
installations
above 4500 ft (1370m)
above
sea level are subject to acceptance
by the local authorities
having
jurisdiction.
N/A -- Not Allowed.
Pressure
switch will not make.
NOTES:
I.
Do not use pipe size greater than these
specified
in table or incomplete
combustion,
flame disturbance,
or flame sense lockout may ocCUrs
2.
Size both the combustion-air
and vent pipe independently,
then use the larger diameter
for both pipes.
3.
Assume
two 45 ° elbows
equal
one 90 ° elbow. Long radius elbows
are desirable
and may be required
in some cases.
4.
Elbows
and pipe sections
within
the furnace
casing and at the vent termination
should
not be included
in vent length or elbow
count.
5.
The minimum
pipe length is 5 ft for all applications.
6.
Use 3-in. diameter
vent termination
kit for installations
requiring
4-in. diameter
pipe.