MAXIMUM ALLOWABLE
VENT PIPE LENGTH (FT) Continued
ALTITUDE
ABOVE
SEA
LEVEL
(FT)
5001 to 60001-
6001 to 70001-
7001 to 80001-
8001 to 90001-
9001 to
I0,0001-
* Wide
radius elbow.
UNIT SIZE
024040
036040
024060
036060
048060
036080
048080
060080
048100
060100
060120
024040
036040
024060
036060
048060
036080
048080
060080
048100
060100
060120
024040
036040
024060
036060
048060
036080
048080
060080
048100
060100
060120
024040
036040
024060
036060
048060
036080
048080
060080
048100
060100
060120
VENT PIPE
DIAMETER
(IN.)*
I-I/2
2
I-I/2
2
2
2-I/2
2-I/2
3
31-no disk
41-no disk
I-I/2
2
I-I/2
2
2
2-I/2
2-I/2
3
31-no disk
41-no disk
I-I/2
2
I-I/2
2
2
2-I/2
2-I/2
3
31-no disk
41-no disk
I-I/2
2
I-I/2
2
2
2-I/2
2-I/2
3
31-no disk
41-no disk
I-I/2
2
1
57
7O
14
6O
4I
7O
29
7O
42
7O
53
7O
13
57
38
7O
27
68
3I
7O
49
66
12
53
36
66
25
63
2O
6I
46
62
1I
49
33
62
23
59
10
35
42
57
2
52
70
9
55
36
70
2I
67
35
70
48
70
8
52
33
70
19
63
24
70
44
65
7
48
3I
65
17
58
13
56
4I
60
6
44
28
60
15
54
NA
30
37
55
5
40
70
NA
48
I7
70
NA
52
I5
70
37
66
NA
44
I5
66
NA
48
NA
67
33
6O
NA
4O
I2
6O
NA
43
NA
41
29
55
NA
35
I0
55
NA
39
NA
I5
25
49
NUMBER OF 90 ° ELBOWS
3
4
47
42
70
70
NA
NA
54
49
23
18
70
70
12
1I
62
57
29
22
70
70
43
38
68
67
NA
NA
50
45
2I
16
68
67
10
9
58
53
18
1I
70
70
39
34
63
62
NA
NA
46
4I
19
14
63
62
8
7
53
48
7
NA
5I
46
36
3I
58
56
NA
NA
42
37
17
12
58
56
7
5
49
44
NA
NA
25
20
32
27
53
5I
38
33
14
9
53
5I
5
NA
44
39
NA
NA
6
35
70
NA
47
8
70
NA
47
9
70
32
64
NA
43
6
64
NA
43
NA
62
28
59
NA
38
NA
59
NA
38
NA
36
24
53
NA
34
NA
53
NA
34
NA
I0
2O
47
024040
036040
024060
036060
2
45
40
31
29
048060
036080
2
30
25
7
NA
048080
060080
2-I/2
57
55
49
47
048100
2-I/2
2I
13
NA
NA
060100
3
54
49
34
29
060120
41- no disk
10
5
NA
NA
1- Vent sizing for Canadian
installations
above 4500 ft (I370m)
above sea level are subject to acceptance
by the local authorities
having jurisdiction.
NA -- Not Allowed.
Pressure
switch will not make.
NOTES:
1.
Do not use pipe size greater than those
specified
in table or incomplete
combustion,
flame disturbance,
or flame sense lockout
may occur.
2. Assume
two 45 ° elbows
equal one 90 ° elbow. Long radius
elbows
are desirable
and may be required
in some cases.
3.
Elbows
and pipe sections
within
the furnace
casing
and at the vent termination
should
not be included in vent length
or elbow
count.
4.
The minimum
pipe length is 5 ft for all applications.