Payne PG9MAA Specification page 9

Multipoise condensing gas furnace
Hide thumbs Also See for PG9MAA:
Table of Contents

Advertisement

MAXIMUM ALLOWABLE
EXPOSED VENT PIPE LENGTH (FT) WITHOUT INSULATION
IN WINTER DESIGN TEMPERATURE
AMBIENT FOR DIRECT-VENT APPLICATIONS*
WINTER
DESIGN
MAXIMUM
PIPE
UNIT
TEMPERATURE
DIAMETER
WITHOUT
SIZE
(°F)
(IN.)
INSULATION
20
I-I/2
51
0
I-I/2
28
-20
I-I/2
I6
040
20
2
45
0
2
22
-20
2
I 0
20
2
65
060
0
2
35
-20
2
20
20
2
55
0
2
48
-20
2
30
080
20
2-I/2
70
0
2-I/2
47
-20
2-I/2
28
20
2-I/2
40
0
2-I/2
40
-20
2-I/2
38
I00
20
3
70
0
3
50
-20
3
28
20
3
70
0
3
61
-20
3
37
I20
20
4
70
0
4
48
-20
4
23
20
3
60
0
3
60
-20
3
44
I40
20
4
70
0
4
57
-20
4
30
* Pipe length (ft) specified
for maximum
pipe lengths
located
in unconditioned
spaces.
Pipes located
in unconditioned
space cannot exceed
able pipe length
as specified
in Maximum
Allowable
Pipe Length
table on pages
6 and 7.
1 insulation
thickness
based
on R value of 3.5 per in.
WITH 3/8-1N. OR
THICKER INSULATIONt
70
70
70
70
70
58
70
70
70
55
55
55
70
70
70
40
40
40
70
70
70
70
70
70
70
70
70
60
60
60
70
70
70
the total al!ow-
m9m