Electric Dryer

PRODUCT MODEL NUMBERS
NED7200T
Electrical: A four-wire or three-wire, single phase,
120/240-volt, 60 Hz, AC-only, electrical supply (or
120/208-volt electrical supply, if specified on the
serial/rating plate) is required on a separate 30-amp
circuit, fused on both sides of the line.
Exhaust venting: Exhaust your dryer to the
outside. 4" (10.2 cm) diameter vent is required.
Heavy metal exhaust vent must be used. Do not use
plastic or metal foil vent. Exhaust outlet hood must
be at least 12" (30.5 cm) from the ground or any
object that may be in the path of the exhaust.
EXHAUST VENTING
Recommended
4" (10.2 cm)
No. of 90°
Rigid
elbows
0
80' (24.4 m)
1
68' (20.7 m)
2
57' (17.4 m)
3
47' (14.3m)
* Do not use non metallic flexible duct.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
PRODUCT DIMENSIONS
NOTE: The height of the dryer from top to floor is 38" (96.5 cm) with the leveling leg screwed
all the way in. The customer can unscrew the leg out an additional 7/8" (2.2 cm) for a total
overall height of 38-7/8" (98.7 cm).
RECESSED AREA AND CLOSET INSTALLATION
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
2" (5.1 cm) front, 0" (0 cm) top, 0" (0 cm) either side and 2-3/8" (6.0 cm) rear.
• Closet front must have two unobstructed air openings combined total area 72"
located 3" (7.6 cm) minimum from trop and bottom.
Louvered door with equivalent air opening is acceptable.
• An appliance installed in a closet shall have no other fuel-burning appliance installed in the
same closet.
ELECTRIC AND GAS DRYER
Weather Hood Type
Use only for short run installation
Metallic Flexible*
Rigid
41' (12.4 m)
74' (22.6 m)
37 ' (11.2 m)
62' (18.9 m)
33' (10.1 m)
51' (15.5 m)
29' (9.0 m)
41' (12.5 m)
A. Overall height: 38" (96.5 cm)
B. Width: 27" (68.6 cm)
C. Depth with door open 90°: 46-7/16" (123.0 cm)
D. Depth: 28" (71.0 cm)
E. Bottom vent location from back to center of hole: 7-1/2" (19 cm)
Side vent hole from back to center of hole: 8-1/2" (21.6 cm)
2-1/2" (6.4 cm)
Metallic Flexible*
33' (10.1 m)
29' (8.8 m)
25' (7.6 m)
21' (6.5 m)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
2
Select the route that will provide the straightest
and most direct path outdoors. Plan the
installation to use the fewest number of elbows
and turns. Avoid making 90° turns.
Do not use vent runs longer than specified in vent
length chart.
Determine the number of elbows you will need.
NOTE: Side and bottom exhaust installations
have a 90° turn inside the dryer. To determine
maximum exhaust length, add one 90° turn to the
chart.
(464.5 cm
2
),
Ref. W10161760
09-05-08