Jet Models (Cg602 & Cg902 Series); Temperature Control - Fisher & Paykel TITAN CG913 Series User Manual

Fisher & paykel cooktop user manual
Hide thumbs Also See for TITAN CG913 Series:
Table of Contents

Advertisement

Temperature control

Choose the control knob for the burner you want to
1
use.
Press down gently and turn the knob anticlockwise
2
to the high
position. All electrodes will spark
until you release the knob. Hold down the knob for
approximately five seconds as releasing it too soon may
extinguish the flame.
Adjust the flame anywhere between the High and Low
3
positions. Do not adjust the flame between High and
Off.
If the cooktop does not light
Check that the cooktop is plugged in and the power is switched on.
Check that the gas is turned on.
Check that the burner parts, including the burner cap, are positioned correctly.
If the burner has not lit within 15 seconds, turn the control knob off and wait at least one minute
before trying again.
A dirty or wet electrode will prevent the burner lighting
efficiently. Clean electrodes with a toothbrush and
methylated spirits.
6
Burner cap
Burner ring
JET MODELS (CG602 & CG902 Series)
High
Correct assembly
Electrode
Off
Low
Incorrect assembly
Thermocouple