Mechanical Troubleshooting – Planer/Jointer
Trouble
Probable Cause
Machine will
No incoming
not start/
power.
restart or
repeatedly
trips circuit
breaker or
blows fuses.
Planer frequently
trips.
Building circuit
breaker trips or
fuse blows.
Motor failure.
Dust chute not
seated properly
on either Jointer
Infeed or Planer
Table
Remedy
1. Verify unit is connected to power and Start/Stop switch is in the
Start position (see Power on page 13).
2. Verify unit is connected to power. Set the Start/Stop switch to
the Stop position, depress and release the reset switch, then
reset the Start/Stop switch to the Start position (see Power on
page 13).
One cause of overloading trips, which are not electrical in nature,
is too heavy a cut. The solution is to take a lighter cut.
Verify that planer is on a circuit of correct size. If circuit size is
correct, there is probably a loose electrical lead.
If electric motor is suspect, have a qualified electrician test the
motor for function or take the machine to a service center and
have it tested.
Adjust the dust chute, making sure that the key on the dust chute
depresses the micro-switch on machine.