USER SETTINGS MENU
The USER can also set certain functions in the USER SETTINGS MENU.
The default settings are shown in bold in the following list. Options are
listed inside the parentheses. Example: the default PROGRAMS PER
DAY is 4 Periods with (0 and 2) as options. See pages 32-33 to change
these settings.
30 o F
1. PROGRAMS PER DAY: 4 Periods
(0, 2, 4)
(0 o C)
2. FILTER CHANGE DAYS: 90 Days
(30-360, in 15 day increments)
3. REFRESH FAN ON TIME: 15 Minutes
(10, 15, 20, 30)
Out of Range
4. CLOCK DISPLAY: ON
"LO"
(ON, OFF)
5. DAYLIGHT SAVING: ON
< 30 o F
(ON, OFF)
6. TOUCHPAD BUZZER: ON
(ON, OFF)
7.
TEMP SCALE: F
(Fahrenheit, Celsius)
8. LCD CONTRAST: 5
(0-9)
34
45 o F
o
(7
C)
Program Range
Display Range
99 o F
95 o F
(37 o C)
o
(35
C)
Out of Range
SYSTEM or US
2 7
"HI"
> 99 o F
44002-01 R111809
US
3