Install Outdoor Unit - Sanyo SAP-K9AP Instruction Manual

Split system air conditioner
Table of Contents

Advertisement

10. INSTALL OUTDOOR UNIT

10.1 Wiring Instructions for the Outdoor
Unit
Regulations on wire size differ from locality.
For field wiring requirements, please refer to
your local electrical codes. Make sure that
the installation fully complies with all local
and national regulations.
1. C9AP, C12AP, C18AP, C25AP
Disassemble the handle on the outdoor
unit right side plate. (Screw x 1pc)
C30AP
Disassemble the front side plate on the
outdoor front side. (Screw x 3pcs)
2. Take off wire clamp, connect and fix
power connect cord to terminal of line
bank. Connect the inter-unit wiring
and power line according to the
drawing on the handle (C9,12,18,25AP)
or front side plate (C30AP).
NOTE
Use the wire clamp to fix the
signal control wire, then
connect to the corresponding
connector.
3. Fix the power connection cable with wire
clamp. (Fig. 24)
4. Be sure to size each wire allowing approx.
10 cm longer than the required length for
wiring, Store excess wiring inside the
cabinet.
5. When connections are completed, check
that all connections are correct as shown
in the wiring system diagram on the
handle / front side plate.
6. Be sure to ground the unit according to
your local codes.
7. Install back the handle / front side plate.
WARNING
Loose wiring may cause the terminal to
overheat or result in unit malfunction.
A fire hazard may also exist. Therefore,
be sure all wiring is tightly connected.
Installation Service
Handle
Handle
Front side
plate
Black
Blue
Yellow-green
Wire clamp
1.
2.
Fig. 24a (C9AP,C12AP)
3
Blue
Yellow-green
Black
Brown
Wire clamp
1.
2.
Fig. 24b (C18AP, C25AP)
N(1)
3
N(4)
5
Blue
Blue
Black
Brown
Brown
Wire clamp
( Factory
supplied
6m )
Fig. 24c (C30AP)
26