How To Install The Outdoor Unit; Wiring Instructions For The Outdoor Unit - Sanyo COOL Installation Instructions Manual

Inverter split system air conditioner
Table of Contents

Advertisement

I For stranded wiring
(1) Cut the wire end with a cutting pliers, then strip the insulation to expose the stranded wiring about 3/8" (10 mm) and
tightly twist the wire ends. (Figs. 11 and 12)
(2) Using a screwdriver, remove the terminal screw(s) on the terminal plate.
(3) Using a ring connector fastener or pliers, securely clamp each stripped wire end with a ring connector. (Fig. 11)
(4) Place the ring connector wire, and replace and tighten the removed terminal screw using a screwdriver. (Fig. 13)
Stranded wire
Fig. 11

4. How to Install the Outdoor Unit

First refer to Section 2. Installation Site Selection.

4-1. Wiring Instructions for the Outdoor Unit

Regulations on wire size differ from locality to locality.
For field wiring requirements, please refer to your
local electrical codes. Make sure that the installation
fully complies with all local and national regulations.
(1) Remove access panel "C". (Fig. 14)
(2) Connect the inter-unit and power supply line
according to the drawing on the panel side.
(3) Be sure to size each wire allowing approx. 4"
(10 cm) longer than the required length for
wiring. Store excess wiring inside the cabinet.
(4) When connections are completed, check that all
connections are correct as shown in the wiring
system diagram on panel side.
(5) Be sure to ground the unit according to your
local codes.
Twist wire ends
Ring
connector
Fig. 12
Special
Screw
washer
Ring connector
Wire
Lock nut
Terminal
block
Conduit
plate
Plug
Inter unit
(Conduit)
14
Screw and
special washer
Terminal plate
Wire
Fig. 13
Cabinet
Access panel "C"
Power supply
(Conduit)
Fig. 14
Ring
connector

Advertisement

Table of Contents
loading

This manual is also suitable for:

HeatDryXhs1271Ch1271Ch1872Xhs1872 ... Show all

Table of Contents