Plan Vent System; Connect Vent - Whirlpool YLEW0050PQ0 Use & Care Manual

240.volt electric dryer
Table of Contents

Advertisement

Available languages

Available languages

Alternate
installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. A close-clearance
installation is shown below.
Refer to the manufacturer's
instructions.
-......
\\\.i
........
_J
Over-the-top
installation (also available with one offset elbow)
Over-the-Top
Installation Kit Part Number 4396028 for close
clearance alternate installation is available for purchase. For
ordering information see "Assistance
or Service."
Special previsions
for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine
vent path
Select the route that will provide the straightest and most
direct path outdoors.
Plan the installation to use the fewest number of elbows and
turns.
When using elbows or making turns, allow as much room as
possible.
Bend vent gradually to avoid kinking.
Use the fewest 90 ° turns possible.
Determine
vent length and elbows needed for best
drying performance
Use the following Vent system chart to determine type of vent
material and hood combinations
acceptable to use.
NOTE: Do not use vent runs longer than those specified in
the Vent system chart. Exhaust systems longer than those
specified will:
Shorten the life of the dryer.
Reduce performance,
resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will
help to achieve the best drying performance.
Vent system
chart
Number of
Type of vent
Box or
Angled
90 ° turns
Iouvered
hoods
or elbows
hoods
0
Rigid metal
90 ft (27.4 m)
80 ft (24.4 m)
Flexible metal
64 ft (19.5 m)
58 ft (17.7 m)
1
Rigid metal
80 ft (24.4 m)
70 ft (21.3 m)
Flexible metal
58 ft (17.7 m)
52 ft (15.8 m)
2
Rigid metal
70 ft (21.3 m)
60 ft (18.3 m)
Flexible metal
50 ft (15.2 m)
42 ft (12.8 m)
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See "Determine vent path" in "Plan Vent System." Avoid 90 °
turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior
of the vent to secure vent.
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. To protect the floor, use a large, flat piece of cardboard from
the dryer carton. Place cardboard under the entire bottom of
the dryer.
2. Slide the dryer on the cardboard until it is close to its final
location. Leave enough room to connect the exhaust vent.
3. Using the coupling supplied with the dryer, connect the
exhaust vent to the coupling and secure with a 4" (10.2 cm)
vent clamp. See illustration below.
A
B
CDE
A. Coupling
B. Vent clamp
C. Vent coupler
D. Vent clamp
E. Rigid or flexible metal vent
If connecting to existing vent, make sure the vent is clean.

Advertisement

Table of Contents
loading

Table of Contents